Detecting Muons with a Siemens Biograph Vision Quadra

Abstract

Atmospheric muons are routinely detected with a variety of instruments, from cloud chambers to scintillation detectors. In this study, we demonstrate that atmospheric muons can also be detected with a clinical long axial field-of-view positron emission tomograph (PET). We performed a blank scan without any radioactive source, using a prototype feature that records all single crystal interactions. The energy a muon deposits in the PET crystals far exceeds the upper limit of the recorded energy range, which means muons cannot be identified through energy discrimination. Instead, we used the scanner's time-of-flight capabilities to select crossing events, i.e. pairs of high-energy single crystal events across the PET gantry whose spatial and temporal separation is consistent with a downward-going ultrarelativistic particle. Random pairings, however, cannot be rejected on an event-by-event basis. We therefore established the muon origin of the crossing events through their characteristic angular distribution. In order to account for geometry and event selection bias, we compare the measured crossing events to a Monte Carlo simulation of muons following the expected angular distribution. This confirms that the measured crossing events in the PET scanner are consistent with atmospheric muons.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lorenzo Mercolli, William M. Steinberger. 2026-11-01. Detecting Muons with a Siemens Biograph Vision Quadra. https://arxiv.org/abs/2611.01845

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Probabilistic Modeling of Photon Interaction Chains in a Silicon Detector

Compton camera imaging relies on the positions and energies of multiple photon interactions recorded in the detector. In silicon detectors that resolve individual interactions, these measurements do not directly provide the causal interaction order, and in nuclear medicine applications the photon may also have scattered in the object before entering the detector. We present a probabilistic model for photon interaction chains in a silicon detector and use it for two inference tasks at the event level: interaction order inference and classification of primary versus object-scattered photons. The model combines photon transport based on Compton scattering and attenuation with a detector response model. It is evaluated on Monte Carlo data for monoenergetic point sources at 140~keV and 511~keV, with and without a cylindrical water phantom. For interaction chains of length two to four, the maximum a posteriori order estimate gives high accuracy in the case without a phantom, exceeding 0.95 for all chain lengths at 511~keV, and decreasing with increasing phantom radius. The gap between the two highest posterior order probabilities provides a confidence measure for the ordering estimate and can be used to increase accuracy at the cost of reduced retention. For scatter classification, likelihood-ratio testing yields receiver operating characteristic curves with area under the curve above 0.85 across all phantom radii considered. These results support the use of probabilistic modeling of measured interaction sequences for inference directly at the event level, and show that both interaction ordering and scatter discrimination can be treated within a common framework.

physics.med-ph↗

Perioperative shear wave elastography for the evaluation of spinal cord release in pediatric dysraphism: first experience in 21 patients

OBJECTIVE Shear wave elastography (SWE) is a recent method for evaluating soft tissue stiffness. Its application to the spinal cord is limited by the ultrasound bone barrier. Spinal dysraphism can cause neurological symptoms impairing bladder, bowel, and lower limb function due to a mechanical stress known as tethered cord syndrome. Detethering of the spinal cord is a part of surgical treatment. This study aimed to assess the feasibility of intraoperative elastography to guide surgery in patients with spinal dysraphism involving traction of the spinal cord. METHODS This single-center retrospective study included all patients who underwent surgery for spinal dysraphism between November 2023 and July 2024. SWE was performed under general anesthesia with the patient in the prone position before and after spinal cord detethering. All SWE measurements were performed using the Aixplorer system. Demographic, clinical, and radiological data (age at surgery, neurological status, and MRI findings) were collected. RESULTS Twenty-one patients with a mean $\pm$ SD (range) age of 3.7 $\pm$ 5.3 (0--17.5) years were included. Etiologies included open saccular dysraphism (n = 3), spinal cord conus lipoma (n = 6), limited dorsal myeloschisis (n = 3), and fibrolipomatous filum (n = 9). In 85% of patients, at least 1 clip was of sufficient quality for analysis both before and after release. The mean $\pm$ SD (range) spinal cord stiffness at the beginning of surgery was 25.2 $\pm$ 9.2 (12.3--39.1) kPa and 11.2 $\pm$ 3.8 (6.2--16.5) kPa at the end of release, with a significant stiffness decrease (p = 0.018). No complications attributable to SWE were observed. CONCLUSIONS SWE of the spinal cord in patients with spinal dysraphism is a safe and feasible imaging method. This technique may assist in assessing the adequacy of untethering during surgery. However, no established normative SWE values for the pediatric spinal cord currently exist. Until it does, the intraoperative interpretability and clinical utility of this technique remain limited.

physics.med-ph↗

Influence of Geometry and Tissue Damage on the Mechanical Behaviour of Skin Meshing

Skin meshing increases graft coverage, yet the clinically achieved expansion often falls below the manufacturer's nominal meshing ratio. Previous elastic analyses have demonstrated that mesh topology and skin anisotropy strongly influence graft expansion; however, the effect of progressive damage at larger deformation remains unexplored. This study therefore investigates how progressive damage affects the expansion and mechanical response of skin meshes. The performance of auxetic mesh geometries is compared with conventional Zimmer mesher (ZM) geometry. Human back skin was modelled using a one-term Ogden ground matrix and a Gasser Ogden Holzapfel (GOH) collagen network, with separate scalar Kachanov-type continuum damage variables for each constituent. The auxetic geometries, including 1st- and 2nd-order alternative slits (AS1 and AS2), I-shaped (IS) and H-shaped (HS) re-entrant patterns, and ZM, were analysed with Langer's lines oriented either parallel or perpendicular to the loading direction. Hyperelastic and damage-based formulations were compared up to 25% strain, and the damage-based simulations were subsequently extended to 40% strain. ZM was further loaded to 155% strain; the area ratios attained by HS at 40% strain were matched by ZM at 142.1% and 124.7% strain for Langer's lines parallel and perpendicular to loading, respectively. Results indicate that HS achieves greater coverage than ZM for a given stretch, whereas its damage advantage depends on the orientation of Langer's lines.

physics.med-ph↗