arXiv Science⌕ Search

arXiv · 2611.01111

Optimal Fan-Out and Break-Even Routing Loss in Waveguide-Integrated Ge-on-Si SPAD Arrays

Abstract

Splitting a waveguide mode over several Ge-on-Si single-photon avalanche diodes (SPADs) relieves dead-time saturation but multiplies dark counts. We quantify this trade-off with the asymptotic count-based information rate, which prices dark counts and dead time in one unit and is attained by an optimally weighted moment estimator. For a non-paralyzable pixel, the information per pre-dead-time signal event peaks at a signal rate $y^*=\sqrt{D(D+1/τ)}$ with exact efficiency $(\sqrt{1+Dτ}-\sqrt{Dτ})^2$, which sets the optimal fan-out and a critical flux above which equal splitting is optimal. We then compare four routing architectures on 64 simulated 16-pixel arrays: an equal passive tree, static trees (uncalibrated, and an idealized calibration-informed benchmark), an ideal programmable tree, and a thermo-optic Mach-Zehnder interferometer (MZI) tree with 1.32 dB excess loss. Ideal programmability gains up to 15.9 dB over equal splitting at low flux. At one known flux, however, the calibrated static splitter beats the MZI tree by 0.14-2.7 dB, and the penalty tends to twice the excess loss when dark counts dominate. In ensemble-median worst-case regret, the MZI tree breaks even only for flux windows wider than 2.55 decades, and not within six decades above about 3.4 dB excess loss. Event-level Monte Carlo simulations reproduce the count statistics and the predicted estimator variances within bootstrap confidence intervals. Sensitivity analyses cover dark-count level, heterogeneity, detector model and random seed. All results are simulations with representative literature parameters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thammarat Yawisit, Pittaya Pannil. 2026-10-31. Optimal Fan-Out and Break-Even Routing Loss in Waveguide-Integrated Ge-on-Si SPAD Arrays. https://arxiv.org/abs/2611.01111

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities

In Positron Emission Tomography, a potential, yet unutilized enhancement, may come from exploiting the quantum entanglement of the annihilation quanta, inscribed in the correlation of their polarizations. To investigate this, we built a PET demonstrator capable of measuring polarization correlations of annihilation quanta by their Compton scattering, based on single-layer scintillator polarimeters. We present a detailed study of the imaging of two $^{68}$Ge line sources, 45 MBq each, to extract the spatial resolution and assess image quality. The results show that a spatial resolution of 2.5$\pm$0.1 mm is obtained using single-pixel events, while resolutions obtained with polarization-correlated Compton events range from 3.6$\pm$0.3 mm to 4.9$\pm$0.3 mm, depending on data selection criteria. We also found that the polarization-correlated Compton events exhibit up to 20% higher average signal to random background ratio compared to the single-pixel events. We also present the first imaging of the NEMA NU-4 phantom filled with a $^{68}$Ga solution of 378 MBq initial activity, successfully combining polarization-correlated events with conventional single-pixel event selection. Based on the extracted spatial resolution, signal-to-background, signal-to-noise, contrast, and contrast-to-noise ratio, we estimate that up to 10% sensitivity increase may be attained by exploiting the polarization-correlated events, while preserving a high image quality.

physics.ins-det↗

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det↗

Residual AM and PM Noise of Selected X-Band Amplifiers

In microwave systems design, amplitude modulation (AM) noise is often ignored relative to phase modulation (PM) noise. However, in high-performance applications requiring ultra-low PM noise, AM noise becomes a critical limiting factor due to AM-to-PM conversion mechanisms. Because AM noise specifications are rarely, if ever, provided for commercial microwave components, this study characterizes the residual AM and PM noise of several 10 GHz amplifiers. We present performance data for various Heterojunction Bipolar Transistor (HBT) amplifier designs and demonstrate the noise reduction achieved through power-summed configurations. For example, a discrete-die GaAs HBT amplifier achieves residual PM noise below $-160$ dBrad$^2$/Hz and AM noise of approximately $-155$ dB/Hz at a 1 kHz offset in a quad power-summed configuration. A notable finding is that the majority of amplifier designs surveyed in this study exhibit higher AM noise relative to their PM noise, with only a few exceptions. The impact of bias supply quality on residual noise is also quantified, demonstrating that the choice of voltage regulator is a first-order design parameter below 1 kHz offset.

physics.ins-det↗