A General-Purpose Adaptable Foundation Model for Total-Body PET Kinetic Modelling

Abstract

Voxel-level kinetic modeling in total-body dynamic positron emission tomography (TB-PET) enables precise physiological quantification but complicates parameter uncertainty estimation. While generative consistency models (CMs) can rapidly estimate Bayesian posterior distributions, they are constrained by type of tracers, kinetic models, and protocols. Training them from scratch whenever a new tracer, model or protocol is used can be computationally intensive. To address this, we introduce LoRACM, a parameter-efficient framework utilizing low-rank adaptation (LoRA) to transfer a pretrained foundation CM to novel TB-PET scenarios. We evaluated three adaptation scenarios using simulated and human data: scanner and protocol transfer for FDG two-tissue compartment modeling; FP-CIT simplified reference tissue modeling; and high-temporal-resolution FDG blood flow imaging via the adiabatic approximation to tissue homogeneity model. Each adaptation was trained in less than 3 hours on a single NVIDIA A100 GPU using 50,000 simulated pairs. In simulations, LoRACM showed strong agreement with results from Markov Chain Monte Carlo (MCMC, which we use as reference posterior distributions), yielding median Kullback-Leibler divergences of 0.05-0.11 and median absolute percentage errors below 1.2% for each kinetic parameter of interest. In human data, LoRACM generated total-body K_i maps comparable to the ones made by non-negative nonlinear least squares (NNLS) fitting and a consistency model trained from scratch. Striatal dopamine binding potential estimates predicted by LoRACM correlated with NNLS estimates (r = 0.968-0.988). LoRACM produced total-body blood flow imaging with FDG matching the one made by NNLS. These underscore the potential of adapting a pretrained CM with LoRA for fast and reliable posterior parameter inference for kinetic models across distinct TB-PET applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yun Zhao, Qinlin Gu, Andrew J. Reader, Yanan Fan, Georgios I. Angelis, Katya Amadita, Kevin J. Chung, Xiaoyu Duan, Benjamin A. Spencer, Guobao Wang, Steven R. Meikle. 2026-10-30. A General-Purpose Adaptable Foundation Model for Total-Body PET Kinetic Modelling. https://arxiv.org/abs/2610.41093

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Probabilistic Modeling of Photon Interaction Chains in a Silicon Detector

Compton camera imaging relies on the positions and energies of multiple photon interactions recorded in the detector. In silicon detectors that resolve individual interactions, these measurements do not directly provide the causal interaction order, and in nuclear medicine applications the photon may also have scattered in the object before entering the detector. We present a probabilistic model for photon interaction chains in a silicon detector and use it for two inference tasks at the event level: interaction order inference and classification of primary versus object-scattered photons. The model combines photon transport based on Compton scattering and attenuation with a detector response model. It is evaluated on Monte Carlo data for monoenergetic point sources at 140~keV and 511~keV, with and without a cylindrical water phantom. For interaction chains of length two to four, the maximum a posteriori order estimate gives high accuracy in the case without a phantom, exceeding 0.95 for all chain lengths at 511~keV, and decreasing with increasing phantom radius. The gap between the two highest posterior order probabilities provides a confidence measure for the ordering estimate and can be used to increase accuracy at the cost of reduced retention. For scatter classification, likelihood-ratio testing yields receiver operating characteristic curves with area under the curve above 0.85 across all phantom radii considered. These results support the use of probabilistic modeling of measured interaction sequences for inference directly at the event level, and show that both interaction ordering and scatter discrimination can be treated within a common framework.

physics.med-ph↗

Perioperative shear wave elastography for the evaluation of spinal cord release in pediatric dysraphism: first experience in 21 patients

OBJECTIVE Shear wave elastography (SWE) is a recent method for evaluating soft tissue stiffness. Its application to the spinal cord is limited by the ultrasound bone barrier. Spinal dysraphism can cause neurological symptoms impairing bladder, bowel, and lower limb function due to a mechanical stress known as tethered cord syndrome. Detethering of the spinal cord is a part of surgical treatment. This study aimed to assess the feasibility of intraoperative elastography to guide surgery in patients with spinal dysraphism involving traction of the spinal cord. METHODS This single-center retrospective study included all patients who underwent surgery for spinal dysraphism between November 2023 and July 2024. SWE was performed under general anesthesia with the patient in the prone position before and after spinal cord detethering. All SWE measurements were performed using the Aixplorer system. Demographic, clinical, and radiological data (age at surgery, neurological status, and MRI findings) were collected. RESULTS Twenty-one patients with a mean $\pm$ SD (range) age of 3.7 $\pm$ 5.3 (0--17.5) years were included. Etiologies included open saccular dysraphism (n = 3), spinal cord conus lipoma (n = 6), limited dorsal myeloschisis (n = 3), and fibrolipomatous filum (n = 9). In 85% of patients, at least 1 clip was of sufficient quality for analysis both before and after release. The mean $\pm$ SD (range) spinal cord stiffness at the beginning of surgery was 25.2 $\pm$ 9.2 (12.3--39.1) kPa and 11.2 $\pm$ 3.8 (6.2--16.5) kPa at the end of release, with a significant stiffness decrease (p = 0.018). No complications attributable to SWE were observed. CONCLUSIONS SWE of the spinal cord in patients with spinal dysraphism is a safe and feasible imaging method. This technique may assist in assessing the adequacy of untethering during surgery. However, no established normative SWE values for the pediatric spinal cord currently exist. Until it does, the intraoperative interpretability and clinical utility of this technique remain limited.

physics.med-ph↗

Influence of Geometry and Tissue Damage on the Mechanical Behaviour of Skin Meshing

Skin meshing increases graft coverage, yet the clinically achieved expansion often falls below the manufacturer's nominal meshing ratio. Previous elastic analyses have demonstrated that mesh topology and skin anisotropy strongly influence graft expansion; however, the effect of progressive damage at larger deformation remains unexplored. This study therefore investigates how progressive damage affects the expansion and mechanical response of skin meshes. The performance of auxetic mesh geometries is compared with conventional Zimmer mesher (ZM) geometry. Human back skin was modelled using a one-term Ogden ground matrix and a Gasser Ogden Holzapfel (GOH) collagen network, with separate scalar Kachanov-type continuum damage variables for each constituent. The auxetic geometries, including 1st- and 2nd-order alternative slits (AS1 and AS2), I-shaped (IS) and H-shaped (HS) re-entrant patterns, and ZM, were analysed with Langer's lines oriented either parallel or perpendicular to the loading direction. Hyperelastic and damage-based formulations were compared up to 25% strain, and the damage-based simulations were subsequently extended to 40% strain. ZM was further loaded to 155% strain; the area ratios attained by HS at 40% strain were matched by ZM at 142.1% and 124.7% strain for Langer's lines parallel and perpendicular to loading, respectively. Results indicate that HS achieves greater coverage than ZM for a given stretch, whereas its damage advantage depends on the orientation of Langer's lines.

physics.med-ph↗