arXiv Science⌕ Search

arXiv · 2610.33759

Development of an FPGA-Based Readout System and Functional Characterization of a Custom NSX1 ASIC for X-ray instrumentation

Abstract

We developed an FPGA-based readout system for a front-end ASIC (NSX1) with 64 channels to read out a large- area silicon drift detector used in X-ray detection instruments such as the Wide Field Monitor module for the STROBE-X mission concept. The FPGA acts as a central controller for the NSX1 configuration, implementing trigger handling and event sequencing, precise event timestamping, control of an external ADC for digitization, and data transfer to the host PC. The system enables comprehensive ASIC characterization; here, we demonstrate preliminary ASIC functionality and characterization tests using a calibrated pulser for two programmable linear gain responses of 375 mV/fC and 750 mV/fC. These preliminary results validate the low-noise performance of the NSX1 ASIC and demonstrate successful integration of the DAQ system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nabin Poudyal, Wayne Baumgartner, Sukanya Chakrabarti, Gianluigi De Geronimo, Wesley Hodge, Peter Jenke, Paul Ray, Jarred Roberts, Eric Wulf. 2026-10-24. Development of an FPGA-Based Readout System and Functional Characterization of a Custom NSX1 ASIC for X-ray instrumentation. https://doi.org/10.1117/12.3109646

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development of an Analog Front-End Using NINO ASIC for Mini-ICAL

The mini-ICAL was supposed to be a pre-prototype detector of the Iron CALorimeter (ICAL) of the India-based Neutrino Observatory (INO) project. Resistive Plate Chamber (RPC) was the active element of these detectors. As this detector operates in avalanche mode, one needs a very fast pre-amplifier for signal processing. NINO ASIC developed for the ALICE time-of-flight detector was a potential chip to be used as the analog-front end. This paper presents an 8-in-1 pre-amplifier board developed using the NINO ASIC, a single-ended to differential signal conversion using the differential driver chip manufactured by Texas Instruments, production of the boards, lessons learned during production, testing of these boards, and interface with RPCs. Finally, its performance based on strip rates and efficiency of the detector will also be discussed.

physics.ins-det↗

Beam performance and data-constrained optical modeling of a UV-transmitting acrylic Cherenkov counter for hadron identification

A threshold Cherenkov counter based on ultraviolet-transmitting (UVT) acrylic has been developed for hadron identification in the S-2S spectrometer at J-PARC. Three 730 mm $\times$ 100 mm $\times$ 50 mm radiators were beam tested: polished UVT acrylic without WLS, UVT acrylic roughened on the four long surfaces without WLS, and polished UVT acrylic containing 10 ppm by mass bis-MSB as a wavelength shifter (WLS). The polished/WLS prototype gave the largest two-ended photoelectron yield among the tested configurations. At a 1-photoelectron software-SUM threshold, its measured detection efficiency remained above 99% throughout the scanned longitudinal range, with no significant degradation up to an average extracted-particle rate of approximately $2.5\times10^{5}~{\rm s^{-1}}$ during beam delivery. Beam observables constrained a Geant4 optical model with one common detector response scale and no PMT-specific response tuning. The model reproduces the observed response hierarchy and main longitudinal trends. In the central |y| < 200 mm region, simulated and measured MPV estimators for the calibration configurations typically agree within about 15%, while larger deviations occur toward the radiator ends, especially for rough/no-WLS. With the calibrated parameters fixed, the model was used to compare unmeasured detector configurations and quantify the momentum dependence of $K^{+}$/p discrimination. In the central, normal incidence geometry, a 90% $K^{+}$-survival working point is predicted to keep proton survival below 3% up to about 1.8 GeV/c. The measurements and constrained extrapolations support the polished UVT/WLS configuration for S-2S and quantify its expected particle-identification reach beyond the simple threshold regime.

physics.ins-det↗

The Intermediate Silicon Tracker Detector for sPHENIX

A new barrel-type silicon detector has been constructed in the central rapidity region of the sPHENIX experiment as part of its charged-particle tracking system. The detector, referred to as the intermediate silicon tracker (INTT), provides single-event timing capability and contributes to charged-particle tracking in combination with the silicon-pixel vertex detector and the time-projection chamber. The INTT consists of two cylindrical barrels with full azimuthal coverage. The inner and outer barrels comprise 24 and 32 silicon strip ladders, respectively. Each ladder consists of four silicon strip sensors, covering the pseudorapidity range $|η| < 1.07$ for collision vertices within $\pm~10$ cm along the beam axis, at radial distances between 72 and 103 mm. The INTT has been fully integrated into the sPHENIX data acquisition system, with detector signals processed by eight FELIX servers. Continuous data taking is enabled by a streaming readout mode, in which detector data are accumulated without hardware triggers, while a conventional trigger-based mode is also supported. The detector achieves stable operation, small inactive area, and high efficiency, providing precise timing, tracking, and vertexing performance during the collection of beam-beam collision data.

physics.ins-det↗