Turning-Point Impact Compromises the Biomechanical Integrity of Cortical Bone during Oscillating Sawing

Abstract

Purpose Oscillating bone sawing is widely used in orthopedic procedures such as total knee arthroplasty, where preservation of the mechanical integrity of the prepared bone surface is essential for implant stability. However, the reciprocating motion of oscillating saws can generate transient impact events near trajectory turning points, potentially inducing surface damage and reducing local load-bearing capacity. This study aimed to investigate the biomechanical consequences of turning-point impact loading during oscillating bone sawing. Methods Oscillating sawing experiments were performed on bovine cortical bone using a conventional trajectory and an optimized trajectory designed to suppress turning-point impacts. Dynamic sawing forces were measured to quantify impact events. Surface damage on the groove wall surface was characterized using scanning electron microscopy (SEM) and optical imaging. Local and global mechanical responses were evaluated using compression tests. Results The conventional trajectory produced pronounced periodic force spikes and generated extensive surface cracks and breakout regions. These impact-dominated events were associated with reduced local compressive strength of the prepared bone surface. In contrast, the optimized trajectory significantly suppressed peak impact forces, resulting in smoother groove wall surfaces with fewer defects. Consequently, the optimized trajectory increased the local compressive strength (p < 0.001) and improved the global compressive strength of the specimens (p = 0.001), while the elastic modulus remained largely unchanged. Conclusion Turning-point impacts during oscillating bone sawing compromise the biomechanical integrity of cortical bone by promoting surface damage and reducing local load-bearing capacity. Suppressing these transient impacts helps preserve the mechanical integrity of surgically prepared bone surfaces.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Han Wang, Urara Satake, Toshiyuki Enomoto. 2026-10-20. Turning-Point Impact Compromises the Biomechanical Integrity of Cortical Bone during Oscillating Sawing. https://doi.org/10.1007/s10439-026-04429-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Integrated Open-Source Framework for Simulation of Transcatheter Pulmonary Valves in Native Right Ventricular Outflow Tracts

Pulmonary insufficiency is a consequence of transannular patch repair in Tetralogy of Fallot (ToF), leading to late morbidity and mortality. Transcatheter native outflow tract pulmonary valve replacement (TPVR) has become common, but assessment of patient candidacy and selection of the optimal device remains challenging. We demonstrate an integrated open-source workflow for simulation of TPVR in image-derived models to inform device selection. Machine learning-based segmentation of Computer Tomography (CT) scans was implemented to define the right ventricular outflow tract (RVOT). A custom workflow for device positioning and pre-compression was implemented in SlicerHeart. Resulting geometries were exported to FEBio for simulation. Visualization of results and quantification were performed using custom metrics implemented in SlicerHeart and FEBio. RVOT model creation and device placement could be completed in under 1 minute. Virtual device placement using FE simulations visually mimicked actual device placement and allowed quantification of vessel strain, stress, and contact area. Regions of higher strain and stress were observed at the proximal and distal end locations of the TPVs where the devices impinge on the RVOT wall. No other consistent trends were observed across simulations. The observed variability in mechanical metrics across RVOTS, stents, and locations in the RVOT highlights that no single device performs optimally in all anatomies, thereby reinforcing the need for simulation-based patient-specific assessment. This study demonstrates the feasibility of a novel open-source workflow for the rapid simulation of TPVR, which, with further refinement, may inform assessment of patient candidacy and optimal device selection.

q-bio.TO↗

Modeling the Microenvironmental Dynamics of Adenoid Cystic Carcinoma in Lacrimal Gland with Treatment Intervention

Adenoid cystic carcinoma (ACC) of the lacrimal gland is a rare and extremely life threatening malignant tumor with a high risk of recurrence and poor long-term outcomes. On the other hand, due to its complex molecular dynamics and low incidence rate, treatment strategies are very limited. In this study, a mathematical model is developed based on the biological phenomena of the tumor microenvironment using nonlinear ordinary differential equations. It is analyzed both analytically and numerically. According to the findings, the growth of tumor cells is associated with the depletion of oxygen and nutrients, while severe hypoxia promotes the development of abnormal blood vessels and makes tumor control more difficult. Surgery and postoperative radiotherapy have been considered as treatment strategies, and we have observed that surgery alone may not be sufficient to prevent the regrowth of residual tumor cells. In addition, postoperative radiotherapy provides better control of the residual tumor burden, particularly when the remaining tumor cells have higher radiosensitivity. Furthermore, different radiotherapy interruption scenarios have been investigated, and the results indicate that longer gaps between radiotherapy doses can adversely affect the overall treatment response, leading to increased overall toxicity and a higher number of residual tumor cells at the end of the observation period. Consequently, our results suggest that postoperative radiotherapy after surgery, combined with adequate radiosensitivity of the residual tumor cells and adherence to the prescribed treatment schedule without prolonged interruptions, may reduce the risk of tumor recurrence and potentially improve long term survival.

q-bio.TO↗

An Octahedral Fibrous Constitutive Model for Heart Valve Mechanics and Function

Fibrous soft tissues derive their nonlinear mechanical response from networks of extracellular matrix fibers. The organization of fibers and their load-bearing characteristics give rise to strain stiffening, the reverse Poynting effect, and anisotropic mechanical behavior. Motivated by these coupled features, we develop an anisotropic hyperelastic model for fibrous biological tissues that accounts for the contribution of the fiber network under both tensile and compressive deformation. The model uses an octahedral arrangement of fibers embedded in a ground matrix, allowing anisotropy, volume fraction, and pre-stretch to influence the material response. We calibrate the model to experimental data for mitral valve leaflets using an inverse finite element approach that is coupled to automatic differentiation to facilitate efficient parameter calibration. The calibrated model reproduces responses across biaxial, pure-shear, and constrained-uniaxial tests, while separate numerical tests demonstrate its ability to represent substantial volume reduction and the reverse Poynting effect. Using the calibrated model, we investigate how anisotropy and fiber reorientation affect valve deformation under physiological loading. The results show that greater leaflet compliance in the radial direction yields proper valve closure, whereas localized fiber reorientation leads to stress concentrations that may promote progressive functional degradation. Widespread reversal of the preferred material directions, by contrast, prevents closure in the simulated valve. Finally, we examine how fiber pre-stretch and collagen volume fraction affect leaflet strain and contact, finding a stronger response to changes in pre-stretch over the parameter ranges studied.

q-bio.TO↗