arXiv Science⌕ Search

arXiv · 2610.26159

The RUBIK satellite payload concept: a 3D-segmented plastic scintillation-based particle tracking detector

Abstract

We present the design concept and first experimental results of RUBIK, a three-dimensional resolving plastic scintillation detector developed as a scientific payload for the Research and Observation in Medium Earth Orbit satellite mission of the Institute of Space Systems of the University of Stuttgart. The name RUBIK is inspired by the Rubik's Cube, a familiar example of a three-dimensional segmented structure, reflecting the 5x5x5 modular arrangement of the sensitive volume. The sensitive volume consists of 125 PVT-based plastic scintillator unit cubes, each penetrated by two perpendicularly aligned wavelength-shifting fibres, which guide scintillation photons to silicon photomultipliers (SiPMs), providing 50 independent readout channels. Custom readout electronics, comprising two discriminator boards with per-channel programmable thresholds, an FPGA-based data-acquisition board, and a dedicated power and bias distribution board, have been developed exclusively from commercial off-the-shelf components. A single-layer prototype with ten readout channels was used for concept validation through SiPM bias voltage and temperature characterisation, and a time-over-threshold based amplitude reconstruction method was validated against radioactive source and cosmic ray measurements. First hit-pattern measurements with 220 MeV protons at a clinical proton therapy facility confirmed that spatially resolved hit clusters consistent with the expected beam geometry were observable in the single-layer readout, demonstrating the capability to resolve particle-induced signal patterns as a first step towards 3D track reconstruction in the full instrument.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roman Bergert, Dzmitry Kazlou, Hartmut Schotte, Niclas Fiedler, Hans-Georg Zaunick, Kilian-Simon Baumann, Kai-Thomas Brinkmann. 2026-10-19. The RUBIK satellite payload concept: a 3D-segmented plastic scintillation-based particle tracking detector. https://doi.org/10.1088/1748-0221%2F21%2F10%2Fp10016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Time performance of USTC-IME LGAD under synchrotron light source focused X-ray

The time performance of Low Gain Avalanche Diodes (LGADs), designed by the University of Science and Technology of China (USTC) and fabricated by the Institute of Microelectronics of Chinese Academy of Sciences (IME), was characterized at the Shanghai Synchrotron Radiation Facility (SSRF). The experiment was conducted at the BL16B1 beamline, which delivers a focused X-ray beam with a diameter of 500 \textmu\text{m}, a repetition period of 2 ns, and a photon energy of 10 keV. Using a fast oscilloscope, waveforms containing continuous signal pulses were recorded within a 50 ns time window. The LGAD under test successfully resolved the 2 ns period of the SSRF. To mitigate pile-up effects and extract pulse-by-pulse information from the acquired waveforms, a waveform-level global template fitting method was employed. The time resolution was then estimated using a combined profile likelihood approach, with a restricted maximum-likelihood (REML) correction accounting for the per-waveform degrees of freedom, yielding a value of 136.8 $\pm$ 0.15 (stat.) $\pm$ 11.9 (syst.) ps. The complete reconstruction and fitting chain was validated end-to-end using simulated waveforms in which the timing deviations of individual large pulses were drawn from Gaussian distributions with fixed standard deviations. The effect of random photon absorption depth on the time resolution of LGADs was studied through dedicated simulations.

physics.ins-det↗

Phonon-dominated thermal conductivity of a superconducting amorphous MoSi thin film

We use the differential 3ω method to directly measure the temperature dependent thermal conductivity for about 90 nm Mo0.78Si0.22 thin films. The measurements are performed in a closed-cycle cryostat to access the temperature range between 50 K and 300 K. The MoSi thin films are capped with Al2O3 and probed with a Pt wire. The results show that the thermal conductivity does not satisfy the Wiedemann-Franz law. This implies that thermal transport in MoSi is not dominated by electrons but by phonon-like excitations, contrary to what is assumed in many electro-thermal models of superconducting devices. We argue that this property might be related to the weak localization visible in the resistivity as a function of temperature curves of the superconductor.

physics.ins-det↗

Demonstration of continuous non-invasive monitoring of plant metabolism using mid-infrared photoacoustic spectroscopy

Life is a rhythmic process driven by cellular and physiological mechanisms that allow plants to respond and adapt to their environment. In addition to natural fluctuations, plants are increasingly exposed to environmental stresses, mainly caused by climate change and anthropogenic pollution. Multiple approaches across different biological scales (gene, cell, metabolite, and physiology) have shed light on acclimation mechanisms but generally lack sufficient temporal resolution. Establishing a non-invasive and high-temporal-resolution monitoring method to measure plant activity across different conditions is therefore needed to fully assess how plant metabolism changes under stress. Here, we established a novel approach to perform continuous and non-invasive mid-infrared photoacoustic spectroscopy on vascular plants, with the aim of identifying and monitoring the chemical composition of peripheral tissues, including sap, over periods ranging from a few minutes to several months. We describe an experimental setup, the physics underlying its operation, and present a multi-day acquisition. Compared with controls, data enabled to identify a diurnal pattern, with peaks of approximately equal duration, that recurred consistently over the experiment. Estimations of the impact of instrumental and environmental fluctuations indicate that the signal amplitude and trends cannot be explained by instrumental drifts. The experiment thus demonstrated the detection of a signal associated with plant physiological activity. While its origins remain to be clarified, this preliminary experiment demonstrates the feasibility of the measurements and provides a basis for future developments.

physics.ins-det↗