Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT

Abstract

Multi-contrast X-ray computed tomography (CT) combines attenuation contrast with phase and dark-field contrast, which are sensitive to refraction and ultra-small-angle scattering, respectively. Common implementations record several intensity measurements per projection angle by phase or mask stepping, which lengthens acquisition and, at a fixed exposure per measurement, raises the dose. Limited-data acquisition via sparse angular sampling or reduced stepping lowers these costs but makes the data less informative, calling for prior information and uncertainty quantification. We study joint Bayesian reconstruction of attenuation, phase, and dark-field images from separately retrieved sinograms. A joint total variation term in the prior couples edge locations across the images but not their values. Posterior sampling with the No-U-Turn Sampler complements maximum a posteriori estimates with pixel-wise uncertainty. We compare this joint prior with channel-wise total variation alone on synthetic and experimental Talbot-Lau interferometry data under full, sparse-angle, sparse-step, and combined acquisition (up to 24 times fewer exposures). Both maximum a posteriori reconstructions suppressed undersampling artifacts, with synthetic relative errors 1.6-11 times lower than those of filtered backprojection. The joint prior gave modest synthetic accuracy gains, a cleaner experimental dark-field background, 23-30 % lower mean dark-field posterior standard deviation, and 4-38% higher median effective sample size in experimental limited-data runs. In the synthetic study, posterior standard deviations matched or exceeded the errors in flat regions but underestimated them at boundaries, especially in phase. Experimental phase chains mixed slowly under angular undersampling. The formulation also applies to edge illumination with adapted forward and noise models.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hassan Yazdanian, Henrik Mäkinen. 2026-10-15. Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT. https://arxiv.org/abs/2610.21406

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

PanoDiff-SR: Synthesizing Dental Panoramic Radiographs using Diffusion and Super-resolution

Interest in generating realistic synthetic medical images has grown in recent years. Such datasets can mitigate the scarcity of public data for artificial intelligence research and support education. Work on synthesizing dental panoramic radiographs (PRs) has so far relied almost exclusively on generative adversarial networks (GANs), and three limitations recur: the synthesized field of view is often restricted to a cropped dentoalveolar region rather than a complete PR; observer studies of GAN-generated PRs report that clinicians still identify synthetic images with accuracies of roughly 78-82%, implying persistent visible giveaways; and adversarial training remains sensitive to instability and mode collapse. Generating a full-size PR directly at diagnostic resolution with a diffusion model is an alternative, but sampling at that resolution is costly. We therefore present PanoDiff-SR, an end-to-end two-stage pipeline developed and evaluated specifically for panoramic radiography: a denoising diffusion implicit model (PanoDiff) generates a low-resolution (LR) seed PR ($256\times128$), which a fine-tuned hybrid attention transformer (HAT) super-resolution (SR) stage upscales to a high-resolution (HR) PR of $1024\times512$. Decoupling the expensive generative step from the resolution step yields complete, full-arch PRs at diagnostic resolution on a single 47 GB GPU. The Fréchet inception distance between 7243 real and synthetic HR images is 40.5. Inception scores were 2.68, 2.38, 2.90 and 2.98 for real HR, synthetic HR, real LR and synthetic LR images, respectively. Six clinical experts, each evaluating 100 synthetic and 100 real PRs under a time limit, distinguished real from synthetic images with an average accuracy of 68.5% (50% corresponds to random guessing), substantially closer to chance than reported for GAN-based studies. Project page: https://s4nyam.github.io/panodiff/

eess.IV↗

Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors

This work presents high-resolution X-ray microtomography based on commercial off-the-shelf (COTS) CMOS image sensors as direct detectors. The system uses a microfocus X-ray source in cone-beam geometry, enabling both absorption-contrast imaging, thanks to the sensor s intrinsic resolution, and phase-contrast imaging, by adjusting the object-to-sensor distance. A dynamic flat-field correction algorithm mitigates radiation-induced sensor degradation during long acquisitions. The setup provides voxel sizes from 3.9 microns to 5.2 microns, with an effective spatial resolution (FWHM) as fine as 9.6 microns in magnified phase-contrast mode (1.33x) and 21 microns in non-magnified absorption-contrast mode. Phase contrast enhances visualization of soft tissue boundaries that are difficult to visualize using absorption-contrast imaging in the same experimental configuration.

eess.IV↗

MorphoBranch: A Fine-Structure-Preserving Workbench for Morphometric Analysis of Branched Cellular Structures

Background and Objectives: Fluorescence-labeled cellular arbors provide readouts of neuronal and microglial morphology, but fine and weakly labeled processes are prone to fragmentation and false connections that bias skeleton-based measurements. We present MorphoBranch, a fine-structure-preserving, human-reviewable workbench for morphometry of branched cellular structures. Methods: MorphoBranch combines a deterministic Morphometry Engine with an LLM-assisted Refinement Engine. The Mor- phometry Engine implements an image-to-graph workflow integrating multiscale structural evidence extraction, hysteresis segmen- tation, evidence-constrained skeleton refinement, and graph-based morphometry. The Refinement Engine maps natural-language requests to registered actions for parameter adjustment, preview execution, metric reporting, and unsupported-request handling, while image processing and quantitative computation remain deterministic and reviewable. Results: MorphoBranch was evaluated on two public neuronal axon datasets, AxonMIP and AxonStack, and the in-house Cell- Morph dataset of microglial fluorescence images. It achieved the highest Skeleton F1 and clDice and the lowest length-estimation error among the evaluated methods on all three datasets, while also achieving the highest Dice and IoU on AxonMIP and Axon- Stack. Across 150 natural-language tasks, the Refinement Engine achieved a 94.0% end-to-end success rate. Conclusions: These results demonstrate that MorphoBranch provides a reproducible, human-reviewable workflow for mor- phometric analysis of branched cellular structures. It supports fine-structure-preserving quantification across neuronal axon and microglial fluorescence images while maintaining inspectable and reproducible analysis workflows.

eess.IV↗