arXiv Science⌕ Search

arXiv · 2610.14144

Planck-Scale Constraints on Quantum Gravity-Induced Neutrino Decoherence with IceCube

Abstract

Many quantum gravity theories predict spacetime fluctuations at the Planck scale. Neutrinos, which interact only via the weak force and gravity, propagate over long distances without losing quantum coherence. Planck-scale fluctuations would spoil that coherence, damping the flavor oscillation probability over long baselines. This makes neutrinos sensitive interferometers for Planck-scale physics. We present a search for quantum decoherence using 368,071 atmospheric neutrinos detected by IceCube in the energy range 0.5-100 TeV, an order of magnitude higher in energy than any previous decoherence search. We find no evidence for decoherence and set the strongest constraints to date on this class of neutrino decoherence models, improving on previous limits by over an order of magnitude for decoherence rate scaling as $E^2$ and $E^3$. These results exclude natural Planck-suppressed decoherence for all energy scalings $E^n$ with $0\leq n \leq 3$, the first such exclusion at the Planck scale for $n=3$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R. Abbasi, M. Ackermann, J. Adams, J. A. Aguilar, M. Ahlers, J. M. Alameddine, S. Ali, N. M. Amin, K. Andeen, C. Argüelles, S. Athanasiadou, S. N. Axani, R. Babu, X. Bai, A. Balagopal V., S. W. Barwick, V. Basu, R. Bay, J. J. Beatty, J. Becker Tjus, J. Beise, C. Bellenghi, S. Benkel, S. BenZvi, D. Berley, E. Bernardini, D. Z. Besson, E. Blaufuss, L. Bloom, S. Blot, F. Bontempo, J. Y. Book Motzkin, C. Boscolo Meneguolo, S. Böser, O. Botner, J. Braun, B. Brinson, Z. Brisson-Tsavoussis, L. Brusa, R. T. Burley, D. Butterfield, K. Carloni, J. Carpio, N. Chau, Y. C. Chen, Z. Chen, D. Chirkin, S. Choi, A. Chubarov, B. A. Clark, D. A. Coloma Borja, A. Connolly, J. M. Conrad, D. F. Cowen, C. De Clercq, J. J. DeLaunay, D. Delgado, T. Delmeulle, S. Deng, P. Desiati, K. D. de Vries, G. de Wasseige, T. DeYoung, J. C. Díaz-Vélez, S. DiKerby, T. Ding, M. Dittmer, A. Domi, L. Draper, L. Dueser, D. Durnford, K. Dutta, M. A. DuVernois, T. Ehrhardt, L. Eidenschink, A. Eimer, C. Eldridge, P. Eller, E. Ellinger, D. Elsässer, R. Engel, H. Erpenbeck, W. Esmail, S. Eulig, J. Evans, P. A. Evenson, K. L. Fan, K. Fang, K. Farrag, A. Fattorini, A. R. Fazely, A. Fedynitch, N. Feigl, C. Finley, D. Fox, A. Franckowiak, S. Fukami, P. Fürst, J. Gallagher, A. Garcia. 2026-10-09. Planck-Scale Constraints on Quantum Gravity-Induced Neutrino Decoherence with IceCube. https://arxiv.org/abs/2610.14144

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Laboratory Characterization of a Ge-CCD Prototype for Future Near-Infrared Astronomical Instrumentation

Germanium charge-coupled devices (Ge-CCDs) extend CCD imaging beyond the silicon cutoff and are candidate detectors for the near-infrared channel of future astronomical instruments, in particular the spectrographs of next-generation wide-field surveys. We report the laboratory characterization at Brookhaven National Laboratory (BNL) of a prototype fabricated at MIT Lincoln Laboratory. We describe the cryogenic test system and readout, and present measurements of the output waveform, dark current, readout noise, and X-ray response. The dark current at 94.69 K is $26.12 \pm 0.08$ e$^-$ pixel$^{-1}$ s$^{-1}$. Under $^{55}$Fe irradiation without on-chip binning, the charge generated by an X-ray is confined within $2\times2$ pixels, and the Mn K$α$ line has a full width at half maximum (FWHM) of $8.5 \pm 0.1$% for single-pixel events. Since the charge generated by X-rays above about 30 keV spreads over $3\times3$ or more pixels, the CCD was operated with $2\times2$ on-chip binning at higher energies. This yielded FWHMs of $8.4\pm0.4$% at 30.9 keV ($^{133}$Ba, ASCA grades 0, 2, 3, 4, and 6) and $7.45\pm0.04$% at 59.5 keV ($^{241}$Am, all grades). These results establish a baseline for the device and for the BNL test system. Measurements of the temperature dependence, optical response, and charge-transfer performance will connect this baseline to the requirements of near-infrared astronomical instruments.

hep-ex↗

A REST-based Monte Carlo Simulation and Data Analysis Framework for the N$ν$DEx Experiment

The N$ν$DEx experiment is designed to search for neutrinoless double-beta decay ($0νββ$) of $\mathrm{^{82}Se}$ and is planned to be deployed at the China Jinping Underground Laboratory (CJPL). It employs a high-pressure time projection chamber (TPC) filled with $\mathrm{^{82}SeF_6}$ gas and a Topmetal pixelated charge readout system. The high $Q_{ββ}$ value of $\mathrm{^{82}Se}$, together with the track reconstruction capability of a gaseous TPC, provides strong potential for background suppression. In this work, we develop a full simulation and reconstruction framework for the N$ν$DEx experiment based on the REST (Rare Event Searches Toolkit) software framework. To meet the detector-specific requirements of N$ν$DEx, customized simulation processes are implemented to describe the detector geometry, electron drift and diffusion, the Topmetal readout plane, signal formation, and electronics response. These developments enable a complete software description of the detector response from energy deposition to digitized waveforms. A waveform-fitting-based reconstruction method is further applied to the simulated signals to extract the deposited charge and reconstruct the event energy. For simulated signal events, the reconstructed energy resolution reaches a full width at half maximum (FWHM) of less than 1\%, satisfying the design requirement of the experiment. The resulting simulation and reconstruction chain provides a basis for future studies of detector response, background rejection, event classification, and optimization of the N$ν$DEx detector design.

hep-ex↗

Characterization of Hamamatsu R11410-23 Photomultiplier Tubes and Performance in the PandaX-4T Detector

The PandaX-4T liquid xenon detector uses Hamamatsu 3-inch R11410-23 photomultiplier tubes (PMTs) as the light sensors for ultra-low radioactivity, high quantum efficiency, and long-term stability of all PMTs at cryogenic temperature. Each PMT was thoroughly tested in a dedicated chamber before being installed in the detector to ensure compliance with experimental requirements. Main PMT characteristics, including gain, dark count rate, and after-pulse probability, were measured and the distributions of these parameters were presented. Additionally, all PMTs were tested in a cryogenic environment to simulate their operating conditions in an actual detector environment. Finally, we report the long-term performance of all PMTs during the commissioning run of the PandaX-4T experiment, and most of the PMTs worked well.

hep-ex↗