arXiv Science⌕ Search

arXiv · 2610.13815

A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy

Abstract

Wireless capsule endoscopy is constrained by severe limitations in size, available power, and reliable data transmission through biological tissues. Although recent advances in miniature imaging sensors have improved image quality, the wireless transmission of color images at practical frame rates remains a challenging task under the tight capsule constraints. We present the design and the experimental validation of a miniaturized Wireless Imaging Transfer (WIT) system for capsule endoscopy based on a sub-GHz IEEE 802.11ah (Wi-Fi HaLow) wireless link. In addition, a preliminary in-vivo validation of Wi-Fi HaLow communication is reported, showing that a stable through-body wireless link can be established across biological tissues in a clinically relevant porcine model. These in-vivo results provide direct experimental support for the adoption of sub-GHz Wi-Fi HaLow for capsule endoscopy applications. Experimental results demonstrate stable wireless image transmission at a resolution of 320x320 pixels, with measured end-to-end data rates above 12 Mbps and a transmission energy efficiency of 20.7 nJ/bit. We also report a detailed power consumption analysis, with a breakdown of the contributions from the imaging sensor, illumination, digital processing, and RF transmission. When all active subsystem contributions are considered, including the camera, digital processing, RF transmission, and illumination at 60% LED brightness, the total power consumption is approximately 477 mW, corresponding to a complete-chain energy consumption of approximately 39.6 nJ/bit. Overall, the measured performance confirms that sub-GHz Wi-Fi HaLow provides a promising trade-off among throughput, robustness, and energy efficiency for wireless imaging in capsule endoscopy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michele Bertozzi, Lorenzo Amelio, Sebastiano Strangio, Nikita J. Greenidge, Benjamin Calmé, Pietro Valdastri, Giuseppe Iannaccone Fellow, Alessandro Catania. 2026-10-09. A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy. https://arxiv.org/abs/2610.13815

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Selective Depthwise Separable Convolution for Lightweight Joint Source-Channel Coding in Wireless Image Transmission

Depthwise separable convolutional (DSConv) layers have been successfully applied to deep learning (DL)-based joint source-channel coding (JSCC) schemes to reduce computational complexity. However, a systematic investigation of the layerwise and ratio-wise replacement of standard convolutional (Conv) layers with DSConv layers in JSCC systems for wireless image transmission remains largely unexplored. In this letter, we propose a configurable lightweight JSCC framework that incorporates a selective replacement strategy, enabling flexible Conv-to-DSConv replacement at different replacement ratios and positions. By varying the replacement ratio, we obtain models with different computational complexities and analyze their impact on reconstruction performance. Furthermore, we investigate how replacements at different encoder and decoder depths influence reconstruction quality under a fixed replacement ratio. Our results show that Conv-to-DSConv replacement at the intermediate layers of the encoder and decoder achieves a favorable complexity-performance trade-off, revealing layer-wise redundancy in DL-based JSCC systems. Extensive experiments further demonstrate that the proposed framework achieves substantial parameter reduction with only slight performance degradation, enabling flexible complexity-performance trade-offs for resource-constrained edge devices.

eess.IV↗

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

Generative MRI reconstruction maps an initial source distribution to the target image distribution along a learned recovery trajectory. Common generative methods, such as diffusion and flow, typically learn fine-grained local dynamics whose integration defines this global mapping, hence requiring many network evaluations at inference. Existing few-step sampling approaches can lower computational burden by approximating large transformations from local dynamics, albeit at the expense of reconstruction fidelity. FLEX-MRI instead partitions recovery into a small number of finite intervals between retained states defined by progressive changes in k-space support, and directly learns the reconstruction change across each interval. Because such finite transitions can admit multiple plausible outcomes, FLEX-MRI combines support-relaxed finite-transition learning with stochastic exploration. During training, randomized k-space sampling masks define finite-transition targets with varying support, while the prediction loss remains unrestricted by each individual mask. At inference, FLEX-MRI perturbs a random subset of currently estimated k-space coefficients, allowing the learned predictor to stochastically explore alternative transition paths. Each predicted state is then reconciled with the acquired measurements through data consistency. We theoretically show that this stochastic exploration induces nonzero transition-level variation through the learned recovery map and data consistency without requiring an auxiliary generative sampler. Experiments on multi-coil MRI datasets show that FLEX-MRI outperforms competing methods while maintaining computational efficiency comparable to few-step baselines.

eess.IV↗

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

eess.IV↗