Deep preferential evolution guided by pairwise comparisons enables motion correction in photoacoustic tomography

Abstract

Motion artifacts in three-dimensional photoacoustic tomography (PAT), caused by extended mechanical scanning of sparse arrays, degrade image quality. Since sparse sampling results in low-quality sub-reconstructions, tracking motion directly is challenging. While final image quality could in principle guide artifact correction, conventional regularizers do not accurately reflect photoacoustic image quality. Here, we introduce deep preferential evolution (DPE), a derivative-free optimization framework where a learned image comparator guides evolutionary search over reconstruction parameters. By learning relative quality differences between same-target image pairs rather than absolute quality scores, the comparator generalized more robustly from simulation to in-vivo images (after unlabeled domain calibration) than an absolute scorer. Comparator-based DPE successfully corrected synthetic motion across diverse anatomies and backgrounds, and it mitigated artifacts from natural, unconstrained motion in human palm images. These results demonstrate that pairwise learned comparison can provide a transferable optimization objective for high-dimensional image restoration when labeled experimental training data are scarce.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Karteekeya Sastry, Yousuf Aborahama, Junhao Zhu, Manxiu Cui, Lihong V. Wang. 2026-10-08. Deep preferential evolution guided by pairwise comparisons enables motion correction in photoacoustic tomography. https://arxiv.org/abs/2610.12273

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector

In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$σ$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.

physics.med-ph↗

A simplified reconstruction of Positron Emission Tomography image using Time of Flight simulated data in Gate 10

Background: Ultrafast Time-of-Flight (TOF) information in Gate 10 simulations enables direct 3D PET reconstruction without scanner-specific modeling. Although such picosecond timing is not achievable in current detectors, simulated data allow exploration of idealized TOF regimes and rapid evaluation of prototype PET designs. Methods: The TOF-driven reconstruction assigns each coincidence to its annihilation position using sub-picosecond timestamps, producing voxelized 3D histograms with flexible voxel size and field-of-view selection. The approach operates directly on Gate-sorted coincidences, requires no corrections, and outputs MHD/DICOM images. Timestamp precision (~10^-13 s) enables localization on the millimeter scale. Results: Full 3D images of the simulated INSPIRE PET scanner are generated in under one second. The method resolves 0.25 mm features in point-source studies and 1.2 mm rods in the Derenzo phantom, reproduces ground-truth activity distributions in image-quality tests, and maintains quantitative stability across geometries. Performance reflects the theoretical benefits of ultrafast TOF rather than current detector capabilities. Significance: This fast, geometry-agnostic reconstruction tool supports early-stage PET prototyping, allowing rapid assessment of spatial resolution, sensitivity, and uniformity without implementing complex reconstruction software. It is broadly applicable to any simulated PET system with sorted coincidences and enables systematic exploration of ultrafast TOF performance in a controlled environment.

physics.med-ph↗

How Can Technology Improve Acetabular and Pelvic Fractures Management in the Operating Room? A Systematic Review

In recent years, there has been a proliferation of literature describing new technologies increasingly integrated into the surgical management of pelvic fractures. However, the available data are heterogeneous, scattered, and sometimes limited to small series or single-center studies. This review aims to present new technologies in the field of pelvic and acetabular fractures and explore their potential benefits for surgeons and patients. The goal is to describe current concepts, advantages, and limitations and to open a discussion about future use and development. The search was conducted through Medline, Central and Embase databases from inception to January 2025 following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) protocol. A total of 841 records were reviewed and 115 studies were included according to the inclusion and exclusion criteria. Technologies such as robotics, navigation, patient-specific management, and 3D printing are being developed for the management of pelvic injuries. These technologies demonstrate greater surgical accuracy without increasing complications. In pelvic and acetabular fractures surgery, new technologies are very attractive and are a promising help for management of these complex injuries and need to be improved before being included in routine care.

physics.med-ph↗