arXiv Science⌕ Search

arXiv · 2610.10161

Wavelength-Resolved Timing of Near-Infrared Scintillation in Gaseous Xenon

Abstract

The near-infrared (NIR) scintillation signal of xenon has the potential to enhance the performance of xenon-based detectors, but a robust understanding of its properties is a prerequisite for its application. In this work, we measure the NIR time response for $α$-particle interactions in gaseous xenon in 12 wavelength bands spanning approximately $(950-1620)\,$nm. The time response is decomposed into a fast (ns-scale) component and a dominant slow ($μ$s-scale) component. The fast-component spectrum coincides with strong atomic emission lines, predominantly 6p$\,\to\,$6s, whereas the slow-component spectrum follows the broad continuum centred around $1.3\,μ$m. The pressure dependence of the continuum can be described by a two-step kinetic model in which the emitting state is formed by a three-body process and depopulated by a two-body collisional process, with density-independent terms in both rates. Interpreting the slower of these as radiative decay yields an intrinsic lifetime of $\sim3\,μ$s. Theoretical calculations identify a neutral-excimer transition $0_u^- \rightarrow 0_g^-$ and an ionic-dimer transition $1/2_{u} \rightarrow 1/2_g$ as plausible candidates for the continuum emission, with the ionic-dimer transition showing better overall agreement with the measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert Hammann, Steffen Form, Humaira Nazneen, Gabriel Schöpfer, Milan Ončák, Teresa Marrodán Undagoitia. 2026-10-07. Wavelength-Resolved Timing of Near-Infrared Scintillation in Gaseous Xenon. https://arxiv.org/abs/2610.10161

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors

We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub- GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and subsequently filtered to achieve a monoenergetic spectrum utilizing the antiresonance feature, characterized by a drop in neutron transmission spectra at 2-keV for scandium. The analyses and conclusions presented are primarily based on simulations, as this study represents a critical first step toward the final goal. We address challenges such as unmoderated high-energy neutrons and gamma backgrounds from neutron capture in the moderator materials. Through optimization of the moderator+filter and shielding geometry, we identify a configuration that achieves the target neutron flux at 2 keV while maintaining subdominant rates of background interactions in simulation. Lastly, we outline a future pathway to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons

physics.ins-det↗

Timing Challenges in Transmission Silicon Detectors for Light Ions

Transmission silicon detectors are widely used in $ΔE$--$E$ telescope configurations for particle identification and timing in nuclear physics experiments. Variations in signal rise time can introduce time-walk effects that degrade time-of-flight measurements, as recently observed in light-ion production experiments at the Neutrons For Science (NFS) facility at GANIL using the Medley setup. This work investigates the influence of particle energy and detector non-uniformity on signal rise time.

physics.ins-det↗

Neural network-based timewalk correction for the Timepix4 ASIC

Timewalk corrections of hybrid pixel detectors conventionally employ heuristic fits performed independently in bins of the relevant input variables. This requires both an explicit functional ansatz and binning scheme, as well as densely populated calibration data whose required size grows rapidly as further input variables are added. This paper presents a timewalk correction for the Timepix4 readout chip based on a compact feed-forward neural network (NN), which learns the dependence directly from the input variables without requiring an explicit functional ansatz or binning. The NN is compared against the fit-based baseline using data from the Timepix4 beam telescope at the CERN SPS in 2025, with $100\,\mathrm{μm}$ and $300\,\mathrm{μm}$ thick planar sensors. Both methods parameterise the timewalk correction as a function of the measured charge and reconstructed intrapixel impact position. With only 20 % of the calibration data, the NN already achieves the same asymptotic time resolutions as the fit-based baseline: $180\,\mathrm{ps}$ and $300\,\mathrm{ps}$ for the two thicknesses, respectively.

physics.ins-det↗