arXiv Science⌕ Search

arXiv · 2610.06457

A software tool for parametric collimator creation for linac-based preclinical irradiation studies

Abstract

Designing custom Cerrobend collimators for linac-based preclinical electron irradiation is labor intensive and susceptible to design inconsistencies. We developed Collimator Creator (CC), an open source parametric workflow that converts aperture dimensions and jig offsets into printable STL models for a collimator mold, collimator shell, Cerrobend holder, and beam degrader. Two designs were fabricated and characterized: a 4.0 x 1.5 cm$^2$ bilateral lung collimator centered on the central axis and a 1.5 x 1.5 cm$^2$ unilateral lung collimator with a 7.5 mm jig offset, each with a 15 mm thick Cerrobend collimator and a 10 mm PLA degrader. Kilovoltage planar images were used to assess aperture geometry and casting uniformity. Radiochromic film was used to measure full width at half maximum (FWHM) and 80%-20% penumbra under conventional and ultra high dose rate (UHDR) electron delivery on a Varian TrueBeam, and off axis leakage was measured with an ionization chamber at conventional dose rate. The cast Cerrobend apertures deviated by less than 0.2 mm from their specified designs. FWHM values were within 3% of the nominal field dimensions, and penumbra ranged from 0.73 to 1.05 mm under conventional and UHDR delivery. Crossline leakage 2 cm beyond the collimator edge was below 2% for both collimators at conventional dose rate. Parametric collimator generation standardized digital design inputs for the two evaluated rectangular linac-based electron fields. Further work will assess specimen-level dosimetry, additional aperture geometries, and Monte Carlo integration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joseph B. Schulz, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, M. Ramish Ashraf, Lawrie Skinner, Edward Elliot Graves, Billy W. Loo Jr, Stavros Melemenidis. 2026-10-05. A software tool for parametric collimator creation for linac-based preclinical irradiation studies. https://arxiv.org/abs/2610.06457

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A simplified reconstruction of Positron Emission Tomography image using Time of Flight simulated data in Gate 10

Background: Ultrafast Time-of-Flight (TOF) information in Gate 10 simulations enables direct 3D PET reconstruction without scanner-specific modeling. Although such picosecond timing is not achievable in current detectors, simulated data allow exploration of idealized TOF regimes and rapid evaluation of prototype PET designs. Methods: The TOF-driven reconstruction assigns each coincidence to its annihilation position using sub-picosecond timestamps, producing voxelized 3D histograms with flexible voxel size and field-of-view selection. The approach operates directly on Gate-sorted coincidences, requires no corrections, and outputs MHD/DICOM images. Timestamp precision (~10^-13 s) enables localization on the millimeter scale. Results: Full 3D images of the simulated INSPIRE PET scanner are generated in under one second. The method resolves 0.25 mm features in point-source studies and 1.2 mm rods in the Derenzo phantom, reproduces ground-truth activity distributions in image-quality tests, and maintains quantitative stability across geometries. Performance reflects the theoretical benefits of ultrafast TOF rather than current detector capabilities. Significance: This fast, geometry-agnostic reconstruction tool supports early-stage PET prototyping, allowing rapid assessment of spatial resolution, sensitivity, and uniformity without implementing complex reconstruction software. It is broadly applicable to any simulated PET system with sorted coincidences and enables systematic exploration of ultrafast TOF performance in a controlled environment.

physics.med-ph↗

How Can Technology Improve Acetabular and Pelvic Fractures Management in the Operating Room? A Systematic Review

In recent years, there has been a proliferation of literature describing new technologies increasingly integrated into the surgical management of pelvic fractures. However, the available data are heterogeneous, scattered, and sometimes limited to small series or single-center studies. This review aims to present new technologies in the field of pelvic and acetabular fractures and explore their potential benefits for surgeons and patients. The goal is to describe current concepts, advantages, and limitations and to open a discussion about future use and development. The search was conducted through Medline, Central and Embase databases from inception to January 2025 following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) protocol. A total of 841 records were reviewed and 115 studies were included according to the inclusion and exclusion criteria. Technologies such as robotics, navigation, patient-specific management, and 3D printing are being developed for the management of pelvic injuries. These technologies demonstrate greater surgical accuracy without increasing complications. In pelvic and acetabular fractures surgery, new technologies are very attractive and are a promising help for management of these complex injuries and need to be improved before being included in routine care.

physics.med-ph↗

A No-Go Framework for Coarse-Grained Effect Prediction in Boron Neutron Capture Therapy: Structural Identifiability Limits and Microscopic Coverage

We establish when coarse-grained observables uniquely determine an expectation-based biological response in boron neutron capture therapy (BNCT). Microscopic target populations are represented by probability distributions, while retained observables are finitely many population-averaged linear descriptors. For an admissible class containing all finitely supported microscopic distributions, exact distribution-free identification holds if and only if the single-target response kernel lies in the span of the constant function and retained descriptors. Thus mean dose, mixed-field component means, and finite moment sets are not generally sufficient under unrestricted microscopic heterogeneity. We also derive irreducible ambiguity and approximation bounds, sharp partial-identification intervals for bounded non-increasing convex survival kernels, a treatment-ranking criterion, and lower-tail and high-exposure bounds. A fixed-total-exposure temporal model distinguishes transient re-sampling from persistent target-specific underexposure, and a marked-Poisson model shows that separate frequency and event-quality marginals need not determine survival. The framework clarifies which microscopic information is lost through BNCT coarse-graining while leaving room for approximation, partial identification, and prediction under independently justified model restrictions.

physics.med-ph↗