Transient Triggering Grid-Forming Synchronization Control Under Voltage and Frequency Dips

Abstract

Grid-forming (GFM) inverters are gaining attention as a promising alternative for conventional synchronous generators in the modern power systems. Unlike conventional synchronous generators, GFM inverters have limited overcurrent capability that makes them vulnerable during large disturbances. During disturbances i.e., voltage and frequency dips, GFM inverters are pushed into current-limited operation to protect the semiconductor switches. This causes the internal angle of the GFM inverters to accelerate and lose synchronism with the rest of the grid. To address this limitation, this article proposes a transient triggering grid-forming (TTGFM) synchronization control to enhance the synchronization stability performance under voltage and frequency dips. This method uses two feedback signals; terminal voltage and the difference between unsaturated and saturated power to adjust the internal angle which is generated by power synchronization loop (PSL) of the GFM inverters. These two signals manipulates the internal reference angle generation that act as a virtual braking mechanism. This mechanism limits the angle acceleration during voltage and frequency dips without requiring an extra supervisory signal or parameters to tune. The proposed method is benchmarked against two state-of-the-art synchronization enhancement schemes and validated through high-fidelity electromagnetic transient (EMT) simulations with a grid dynamic equivalent (GDE) model in MATLAB/Simulink\textsuperscript{\textregistered}. An analytical framework is developed to derive the synchronization instability mechanism and the critical limits of the stability margins. Generalization of the GDE model further shows that the TTGFM control is not restricted to a single configuration but is applicable to any standard benchmark system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dewan Mahnaaz Mahmud, Vinu Thomas, Bogdan Marinescu, Mickaël Hilairet. 2026-09-30. Transient Triggering Grid-Forming Synchronization Control Under Voltage and Frequency Dips. https://arxiv.org/abs/2609.39719

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Overcoming Cognitive Distraction and Measurement Noise: Strategies for Humans and Engineering Systems

Cognitive distraction and measurement noise are two distinct factors that significantly impact the performance of humans and engineering systems. Cognitive distraction occurs when an individual's attention is diverted from a task, while measurement noise refers to the random variation that can occur in system measurements. Although humans and engineering systems employ different methods to overcome these obstacles, the ultimate goal is to achieve optimal performance. An intriguing question arises: what are the similarities and differences between using the term "noise" in engineering and cognitive psychology? Additionally, it is worthwhile to explore whether the human brain and engineering control systems use similar or different approaches to attenuate noise. While this article does not provide a definitive answer, it emphasizes the importance of addressing this question and encourages further investigation. Furthermore, assistive cyber-physical devices such as wearable sensory-substitution navigation aids are highlighted as quintessential human-in-the-loop systems where engineering noise attenuation and human cognitive distraction mitigation must converge.

eess.SY↗

A Fully Analog Implementation of Model Predictive Control with Application to Buck Converters

This paper proposes a novel approach to design analog electronic circuits that implement Model Predictive Control (MPC) policies for dynamical systems described by affine models. Effective approaches to define a reduced-complexity explicit MPC are combined and applied to realize an analog circuit comprising a limited set of low-latency, commercially available components. The practical feasibility and effectiveness of the proposed approach are demonstrated through its application in the design of a novel controller for DC-DC Buck converters. We formally analyze the stability of the resulting system and conduct extensive numerical simulations to demonstrate the control system's performance in rejecting line and load disturbances.

eess.SY↗

Graph Neural Ordinary Differential Equations for Power System Identification with Transfer Learning Applications

With the shift towards decentralized energy generation, the increasing complexity of power systems renders physics-based modeling challenging. At the same time the growing amount of available measurement data opens the door for obtaining data-driven models. A modern method to do so are neural ordinary differential equations (NODEs), offering a framework for continuous-time system identification. Recent extensions, so called graph NODEs impose a structural inductive bias that has the potential to improve generalization of the learned representations. In this work, we employ and extend them to develop message-passing graph NODEs (MPG-NODEs) for identification of coupled systems with heterogeneous node dynamics and heterogeneous edge couplings. This includes state-of-the-art machine learning architectures to infer latent representations of unmeasured states, local node and edge embeddings to account for heterogeneity as well as an autoregressive scheme to allow for piecewise constant control inputs. We apply MPG-NODEs to identify voltage and frequency dynamics of power systems and compare them to a monolithic NODE under identical measurement assumptions. Our case study indicates that while achieving similar performance, our proposed MPG-NODEs are more flexible with transfer learning options that allow to add or remove edges and nodes with little retraining.

eess.SY↗