arXiv Science⌕ Search

arXiv · 2609.36342

A portable neutron scatter camera with isotropic sensitivity

Abstract

We describe the design and characterization of a neutron scatter camera specifically developed for the study of neutron fields (flux, energy, direction) in experimental areas of spallation facilities, where multiple neutron sources can simultaneously contribute. A combination of hardware and logic triggers provides the isotropic response required for this application. Neutron source locations are accurately reconstructed on images from a built-in 360$^\circ$ panoramic camera. The full understanding of neutron fields that the device provides can be used for site selection and abatement of neutron backgrounds affecting sensitive instruments such as coherent elastic neutrino-nucleus scattering (CE$ν$NS) detectors to be located at the upcoming European Spallation Source.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. G. Yoon, L. Larizgoitia, C. M. Lewis, F. Monrabal, J. I. Collar. 2026-09-28. A portable neutron scatter camera with isotropic sensitivity. https://arxiv.org/abs/2609.36342

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kilopixel Performance of the Kinetic Inductance Detectors for the Terahertz Intensity Mapper

We characterize a flight-grade array of lumped-element kinetic inductance detectors (LEKIDs) developed for the long-wavelength module of the Terahertz Intensity Mapper (TIM). From an 864-pixel science array, we select 490 well-isolated resonators spanning the focal plane and readout band and measure their thermal response, optical responsivity, and noise using a ZCU111-based multitone readout system intended for flight. The thermal and optical response of the detector population is consistent with previous single-pixel measurements and can be described by Mattis-Bardeen theory under the influence of a change in Cooper pair or quasi-particle density. Under increasing blackbody loading, the measured noise transitions from a thermal generation-recombination-dominated floor to photon-noise-limited scaling, with the majority of detectors achieving photon-noise-limited operation by approximately 400 fW incident power, with a median detector noise-limited NEP of $NEP_{det} = 1.1\times10^{-17} W \sqrt{Hz}$. The measured photon-noise scaling implies a median optical efficiency of approximately 0.67, indicating additional unknown loss sources between the detectors and blackbody radiator, tentatively attributed to losses in the waveguide. These results demonstrate that the TIM LEKID architecture retains the required sensitivity when scaled to kilopixel-class arrays; the principal remaining challenges are array-level tone optimization, resonator tracking, and identification of frequency-domain collisions.

physics.ins-det↗

Three-dimensional Compton imaging of undepleted volumes of germanium detectors

The shape of the undepleted volume of a p-type Broad Energy Germanium detector has been imaged at various bias voltages by measuring spatially-resolved three-dimensional Compton-scattering efficiency. The bias voltage was raised stepwise from $-50\,\text{mm}$ to the full-depletion voltage.The geometric acceptance was determined at full depletion. Below full depletion, the relative acceptance observed for $2\times2\times2\,\text{mm}^3$ voxels was used to create the image of the undepleted volume for each bias voltage. The images were fitted with predictions from the open-source software package SolidStateDetectors$.$jl to extract the radial impurity density profile of the detector. The strong radial decrease in the impurity density obtained in the outermost centimeter was validated using independent capacitance measurements. This novel method to determine the impurity density via three-dimensional Compton-scattering efficiency maps provides a powerful tool for advanced detector bulk characterization.

physics.ins-det↗

Development and Performance Study of a Capillary Liquid Scintillator Neutron Detector

Capillary liquid scintillator detectors are promising for high-resolution neutron imaging, yet experimental data on their light spread mechanism and spatial performance remain limited. Here, we report a neutron detector based on a hexagonal capillary array filled with EJ-309 liquid scintillator, with an inner diameter of about 50 um and a camera readout of 9 um pixels. Laser experiments show that the FWHM of the full light spot decreases from 260 um to 90 um with a metal light absorber, confirming effective suppression of lateral light spread. Using an AmBe neutron source, an effective field of view with a 5-sigma threshold was established from background frames. For single-capillary events, the pulse height spectrum follows a Landau distribution with a most probable value of 0.133 +/- 0.001 (stat.), and the intrinsic detection efficiency is 10.07% +/- 1.26% (stat.) +/- 1.43% (syst.), corresponding to about 13.55% when normalized to the active liquid scintillator area. The point spread function core yields a radial FWHM of 12.8 um and a centroid positioning precision of approximately 5.5 um (1 sigma), while the intrinsic position resolution is limited by the capillary pitch to 54 um. Linearity is good for 1 to 2 capillaries, with deviation appearing for 2 to 3 capillaries due to additional capture of spread light. These results provide experimental basis and physical understanding for imaging applications of capillary liquid scintillator neutron detectors.

physics.ins-det↗