Optimal Measurement Selection for Certifiable Voltage Monitoring in Power Distribution Systems

Abstract

Maintaining consumer-end voltages within mandated limits is a central task in operating power distribution systems. Rising penetration of distributed generation, electric vehicles, and flexible loads complicates this task, while a scarcity of real-time measurements leaves distribution networks largely unobservable. Operators commonly monitor a few bellwether meters, which indicate operational health but certify nothing about the unmeasured buses. This work asks how to select measurements that are reported in real time and can certify network-wide voltage-limit compliance. We first illustrate the geometry of the measurement values that certify voltage safety at unmeasured nodes. Building on this geometry, we formulate a bilevel optimization that selects measurements to maximize certification capability, introducing a novel safety-violation metric with favorable monotonicity properties. We derive a strong-duality-based single-level reformulation and two scenario-reduction schemes with quantifiable suboptimality. Numerical tests on the SCE 56-bus system corroborate the superior certification capability and computational efficiency of the proposed approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peng Zhang, Line Roald, Manish K. Singh. 2026-09-23. Optimal Measurement Selection for Certifiable Voltage Monitoring in Power Distribution Systems. https://arxiv.org/abs/2609.28785

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A Lyapunov-Based Small-Gain Theorem for Fixed-Time ISS: Theory, Optimization, and Games

We develop a Lyapunov-based small-gain theorem for establishing fixed-time input-to-state stability (FxT-ISS) guarantees in interconnected nonlinear dynamical systems. The proposed framework considers interconnections in which each subsystem admits a FxT-ISS Lyapunov function, providing robustness with respect to external inputs. We show that, under an appropriate nonlinear small-gain condition, the overall interconnected system inherits the FxT-ISS property. In this sense, the proposed result complements existing Lyapunov-based smallgain theorems for asymptotic and finite-time stability, and enables a systematic analysis of interconnection structures exhibiting fixed-time stability. To illustrate the applicability of the theory, we study feedback-based optimization problems with time-varying cost functions, and Nash-equilibrium seeking for noncooperative games with nonlinear dynamical plants in the loop. For both problems, we present a class of non-smooth gradient or pseudogradient-based controllers that achieve fixed-time convergence without requiring time-scale separation and using real-time feedback. Numerical examples are provided to validate the theoretical findings.

eess.SY↗

Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation

Passive grid impedance estimators that return a single resistance--inductance pair cannot represent a grid whose phase impedances are unequal. This paper identifies a separate pair for each phase from recorded point-of-common-coupling (PCC) voltage and current without injected perturbations. In each phase, the unknown grid-source voltage is cancelled by a periodic difference (PD) or by a second-order-generalized-integrator notch difference (SOGID), and moving-window integration (MWI) replaces the current derivative by an integral and an endpoint feature. The resulting two-parameter regression requires a period or notch-frequency estimate but no phase-locked-loop angle. A voltage-balance analysis gives the source residual left by frequency mismatch and bounds the parameter error by the ratio of this residual to the conditioning of the two features. In the unequal-phase interval (8.3--9.8~s) of a 10-s EMTP grid-forming record, SOGID-MWI attains phase-averaged R/L errors of 5.09/0.33\%; a shared value has a minimum error of 41.67\% for the phase ratio 1:0.5:2. On a 50-s constant-impedance grid-following record, the errors are 0.56/0.06\% over the 20--30-s synchronization disturbance. In a controlled 40-dB noise study, a noise-referenced update rule reduces the white-noise GFL error from 55.9/65.0\% to 12.3/11.5\%.

eess.SY↗

Physics-Guided Inferencer-in-the-Loop Digital-Twin for Real-Time Adaptive Emulation of Nonlinear PMSMs

A real-time digital-twin (RTDT) of a permanent magnet synchronous machine (PMSM) allows drive controllers to be tested in hardware-in-the-loop (HIL) before they meet the real machine. Its machine model rests on identified parameters or flux look-up tables (LUTs) from finite-element analysis (FEA) or characterization tests; the maps are regenerated offline when the machine changes, and online estimators track a few parameters such as resistance and PM flux. This article makes the executed model learnable from reference data. A physics-guided machine learning (PGML) network advances the currents and predicts torque in one step, trained with analytical one-step labels. In the proposed Inferencer-in-the-Loop (IIL) architecture, a GPU retrains the network while a field-programmable gate array (FPGA) executes the last accepted weights. For damper circuits, shifted parameters, and an FEA-calibrated saturated machine, one kernel form reaches average normalized mean absolute errors (NMAEs) of 0.19%-0.67% at measured FPGA kernel latencies of 0.30-0.34 $μ$s, and retraining for a shifted machine nears its final loss within 94 s. On a magnetically linear 200-W drive, a residual form corrects the analytical step and learns its physical parameters from operating data; each step takes under 2.5 $μ$s, 20 times faster than real time and ahead of the physical drive's measurements even at 20-kHz sampling. On six held-out runs (1193 s), its $i_q$ error is 5.9%-9.4% of measured RMS, against 10.4%-13.2% for an independently fitted grey-box model, and over 30 min of loaded heating its online-updated heads track a 4.1% winding-resistance rise with an RMS error of 0.44 m$Ω$.

eess.SY↗