arXiv Science⌕ Search

arXiv · 2609.28661

Cross-geometry transfer and model collapse in point cloud calorimeter shower generation

Abstract

Particle shower simulation is a major computational cost in high-energy physics. Monte Carlo methods such as Geant4 are accurate but expensive, while most machine learning surrogates are tied to specific detector geometries and require retraining for each design change. We study cross-geometry transfer learning with CaloClouds II, a generative model that produces point clouds rather than voxels and can project onto arbitrary detector readouts. We pre-train on photon showers in the International Large Detector (ILD) and adapt to electron showers in the cylindrical CaloChallenge Dataset 3. With only 100 target showers, fine-tuning reduces the geometric mean Wasserstein distance to Geant4 by about 51% over training from scratch. Bias-only fine-tuning (BitFit) stays within 5% of full fine-tuning while updating only 17% of the diffusion network parameters. We also examine model collapse in CaloClouds II by retraining its normalising flow and diffusion model on its own generated showers across successive generations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thorsten Buss, Frank Gaede, Gregor Kasieczka, Lorenzo Valente, Duncan Weber. 2026-09-23. Cross-geometry transfer and model collapse in point cloud calorimeter shower generation. https://arxiv.org/abs/2609.28661

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Physics at the Edge: Benchmarking Quantisation Techniques and the Edge TPU for Neutrino Interaction Recognition

This work presents a benchmark of quantisation techniques for convolutional neural networks applied to neutrino interaction recognition, motivated by the need for low-power inference close to the detector in future liquid argon time-projection chamber (LArTPC) experiments. Using simulation of a generic LArTPC, four Keras models are trained to classify neutral-current, muon-neutrino charged-current and electron-neutrino charged-current interactions, quantised using post-training integer quantisation and quantisation-aware training, and deployed on the Google Coral Edge TPU. Latency and energy per event are compared with those of an Intel Core i7-13650HX CPU, a consumer NVIDIA RTX 4060 GPU and a data-centre NVIDIA A100 GPU, using measured energy at different batch sizes and thread counts; the energy of the Edge TPU is estimated from its nominal power. The accuracy degradation is strongly model-dependent: InceptionV3 shows no significant loss along either pipeline, whereas the other models are substantially degraded. At batch size 1, the Edge TPU is comparable to or faster than the CPU and 1.3-6.5 times slower than the A100, while requiring 5--70 times less energy per event than the other devices; with batching, the GPUs reduce this gap to a factor of 2.6-7.2. The Edge TPU is also approximately four times cheaper than the consumer GPU and more than two orders of magnitude cheaper than the A100. Its low power per device eases deployment where power and cooling are constrained, with an additional benefit in terms of environmental impact. This paper explores possible future integrations of edge AI technologies with neutrino physics.

physics.ins-det↗

Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM

Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay.

physics.ins-det↗

Development of high-resolution timing technique in the past 25 years

This paper reviews recent progress in high-resolution timing, rate capability, and aging performance of particle detectors in the context of developments over the past 25 years. It focuses on MCP, SiPM, LGAD, 3D silicon, and SiEM detectors and compares their performance with that of gaseous timing detectors. In addition, preliminary results from a simplified simulation program, Mini-TCAD, are presented, indicating that hexagonal 3D silicon cells may provide better drift-time uniformity and timing resolution than square cells.

physics.ins-det↗