Cryogenic performance and long-term stability of Hamamatsu R8520-506 photomultiplier tubes in liquid argon

Abstract

Seven Hamamatsu R8520-506 photomultiplier tubes were characterized at room temperature and in liquid argon to evaluate their response and operating stability for liquid-argon light readout. A 405~nm pulsed light source was used to measure gain, peak-to-valley ratio, single-photoelectron charge resolution, and afterpulsing, while dark-count data were acquired with random triggers in the absence of active illumination. Gain and dark-count stability were monitored during a ten-day operating period in liquid argon. At a motherboard input voltage of 900~V, the extracted gains in liquid argon were approximately 27.8\%--51.3\% higher than the corresponding room-temperature values. For all seven tubes, the peak-to-valley ratios were higher and the single-photoelectron charge resolution improved in liquid argon. The dark count rates ranged from approximately 143 to 252~Hz at room temperature and from 166 to 199~Hz in liquid argon, with three tubes showing increases and four showing decreases. The mean number of detected afterpulses per selected primary event was approximately 21.0\%--63.6\% lower in liquid argon. The relative standard deviations across the ten daily means of gain and dark count rate did not exceed approximately 2.1\% and 3.3\%, respectively. The measurements provide a quantitative basis for considering R8520-506 tubes as photosensor candidates for liquid-argon detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jilong Yin, Gaoshuang Li, Yike Shu, Yi Wang. 2026-09-23. Cryogenic performance and long-term stability of Hamamatsu R8520-506 photomultiplier tubes in liquid argon. https://arxiv.org/abs/2609.27718

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kinematic Fitting of electromagnetic calorimeter data - an improved method

Kinematic fitting is widely used in particle physics experiments as a powerful tool to improve experimental resolutions, to suppress background and to provide selection criteria for the identification of specific reactions. Kinematic fitting methods, however, typically assume that the fitted quantities follow Gaussian distributions; an assumption which does not always hold. This is particularly true for energy measurements from electromagnetic calorimeters. This issue can largely be overcome by performing a transformation of the non-Gaussian variables into variables which follow a Gaussian distribution. The new adapted kinematic fitting procedure allows to better account for the non-Gaussian nature of the measured calorimeter energies, at the same time improving the accuracy and robustness of the kinematic fit. This leads to improved pull and confidence-level distributions of the kinematic fit as well as improved invariant mass distributions and signal-to-background ratios in the final event sample.

physics.ins-det↗

Radiation hardness characterization of SiPM sensors for Low Earth Orbit space missions

This work presents a comprehensive radiation hardness characterization of SiPM devices for space-based applications: FBK NUV-HD-MT and NUV-HD-LowCT (1$\times$1, 3$\times$3, and 6$\times$6~mm$^2$) and Hamamatsu S14160 MPPCs with equivalent active areas. Total Ionizing Dose (TID) tests were performed at the ESA/ESTEC Co-60 facility with a level of dose up to 20~krad in silicon, while displacement damage effects were evaluated using 100~MeV protons with a fluence up to $1.12\times10^{11}$~p/cm$^2$ at the Paul Scherrer Institute. Radiation damage in SiPMs manifests through two main mechanisms: ionizing energy loss and non-ionizing energy loss (NIEL), which increases dark current and dark count rate. In this work, breakdown voltage, dark current, and quenching resistance were systematically measured as functions of accumulated dose and fluence. Gain and dark count rates were indirectly measured from the characterized electrical parameters. Both technologies exhibit remarkable stability of most of the functional parameters across all dose levels, while dark current shows predictable increases significantly more pronounced under proton irradiation due to displacement damage. Based on these results, both FBK and Hamamatsu devices are confirmed suitable for Low Earth Orbit (LEO) mission environment.

physics.ins-det↗

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det↗