Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

Abstract

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Garrett Alston, Nancy Love, Rabab Haider. 2026-09-21. Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development. https://arxiv.org/abs/2609.25437

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Failure-Aware Iterative Learning of State-Control Invariant Sets

In this paper, we address the problem of computing maximal state-control invariant sets for deterministic linear systems using failing trajectories. We introduce the concept of state-control invariance, which extends control invariance from the state space to the joint state-control space. The maximal state-control invariant (MSCI) set simultaneously encodes the maximal control invariant set (MCI) and, for each state in the MCI, the set of control inputs that preserve invariance. We prove that the state projection of the MSCI is the MCI and the state-dependent sections of the MSCI are the admissible invariance-preserving inputs. Building on this framework, we develop a Failure-Aware Iterative Learning (FAIL) algorithm for deterministic linear time-invariant systems with polytopic constraints. The algorithm iteratively updates a constraint set in the state-control space by learning predecessor halfspaces from one-step failing state-input pairs, without knowing the dynamics. For each failure, FAIL learns the violated halfspaces of the predecessor of the constraint set by a regression on failing trajectories. We prove that the learned constraint set converges monotonically to the MSCI. Numerical experiments on a double integrator system validate the proposed approach.

eess.SY

Consensus and Synchronization of Multi-agent Systems over Finite Fields - Graph Topologies

This paper presents cooperative protocols for multi-agent systems with agents having a finite state-space. Both scalar single-integrator consensus and general LTI system synchronization are considered. Systems having a finite state-space describe agents with minimal memory capacity processing only a finite alphabet. Such systems are remarkably resilient to communication noise. The crucial problem, however, is to construct the admissible communication topology, which is NP-hard. We address this by efficiently exploring the subsets of admissible graph matrices and propose two new algorithms to generate them. Simulations validate the proposed approach.

eess.SY

Extracting Exact Lie Derivatives Without Backpropagation: A Dual Compiler for Neural Control Barrier Functions

A safety filter based on a neural control barrier function (CBF) deployed in an embedded control loop evaluates, at each control cycle, the trained network and its Lie derivatives along the system vector fields, under the memory and worst-case execution time (WCET) constraints that safety-oriented coding standards impose. Reverse-mode automatic differentiation, by which training frameworks obtain these derivatives, retains an activation cache whose size grows with the sum of the layer widths, and general-purpose differentiation runtimes allocate the computational graph from the heap at each call. This paper presents a compiler that evaluates a neural CBF and its exact Lie derivatives by forward-mode dual-number arithmetic. The compiler emits self-contained C++ code in which a single forward pass, without backpropagation, returns the barrier value and its exact Lie derivative along a given vector field; the drift and input Lie derivatives of the safety constraint are obtained from one such pass per vector field, and a second-order extension based on hyper-dual numbers returns the exact second-order Lie derivatives required by CBFs of relative degree two. The dual forward pass requires a workspace bounded by four times the widest layer, independent of network depth, and the emitted code contains no allocation call sites, so the absence of dynamic allocation is verifiable by inspection of the code. On an ESP32-S3 microcontroller, the compiled filter assembles the complete safety constraint in under one millisecond from statically allocated buffers of at most 768 bytes, and the maximum execution time over 1000 evaluations lies within 5% of the median in all three examples, whereas a heap-allocating reverse-mode baseline shows maxima 33% and 70% above its median in the two first-order examples. The compiler and the embedded experiments are released as open-source software.

eess.SY