arXiv ScienceSearch

arXiv · 2609.25374

Angular momentum analysis on Karate roundhouse kicks: a longitudinal case study

Abstract

Human gait in reality extends beyond straight-line walking, with some situations even requiring drastic back-and-forth rotations. A smooth and stable execution may seem intuitive, but the underlying mechanics remains unknown. The Karate roundhouse kick may be an extreme case of exhibiting dynamic back-and-forth rotations, but investigating the angular momentum (AM) management can potentially inform stability analysis in dynamic human motions and smoother gait in robots and exoskeletons. This paper introduces two new AM-based measures and analyzes AM-related variables to study the target-less retractable back-leg Karate roundhouse kick. The purpose is to understand the underlying AM management, analyze the differences between stable and unstable kicks, and investigate how these variables and measures change over time with improvement. A one-year longitudinal study was conducted with the first author as a Karate student, and a Karate instructor was also recruited for one session as an expert, whose data is used for comparison. Results show that unstable kicks have higher peak total AM before Strike and smaller braking peak after Strike. The proposed AM-based measures are able to identify the cause of some unstable kicks, though no clear distinction could be made between stable and unstable kicks since kicks can be unstable for different reasons. Nonetheless, the proposed measures can be applied as performance measures to analyze other types of dynamic motions. To incorporate them as stability criteria, however, it is recommended to also consider their coordination with time, kinematics, and center of pressure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jan C. L. Lau, Christian Mele, Jonathan Feng-Shun Lin, Katja Mombaur. 2026-09-21. Angular momentum analysis on Karate roundhouse kicks: a longitudinal case study. https://arxiv.org/abs/2609.25374

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

J-PARSE: Jacobian-based Projection Algorithm for Resolving Singularities Effectively in Inverse Kinematic Control of Serial Manipulators

J-PARSE is an algorithm for smooth first-order inverse kinematic control of a serial manipulator near kinematic singularities. The commanded end-effector velocity is interpreted component-wise, according to the available mobility in each dimension of the task space. First, a substitute ''Safety'' Jacobian matrix is created, keeping the aspect ratio of the manipulability ellipsoid above a threshold value. The desired velocity is then projected onto non-singular and singular directions, and the latter projection scaled down by a factor informed by the altered mobility. A right-inverse of the non-singular Safety Jacobian is applied to the modified command. In the absence of joint limits and collisions, this ensures safe transition into and out of low-mobility configurations, guaranteeing locally stable reaching behavior towards target poses within, on the boundary of, and outside the workspace. The behavior is further guaranteed to be locally asymptotically stable if the starting and target configurations are not exactly singular, even if they are nearly singular. Velocity control with J-PARSE is benchmarked against approaches from the literature, illustrating its use of a single tuning parameter to simultaneously achieve high reaching accuracy and stable behavior. Applications in teleoperation, servoing, and learning are demonstrated. Videos and code are available at https://jparse-manip.github.io/.

cs.RO

NeMo-map: Neural Implicit Flow Fields for Spatio-Temporal Motion Mapping

Safe and efficient robot operation in complex human environments can benefit from good models of site-specific motion patterns. Maps of Dynamics (MoDs) provide such models by encoding statistical motion patterns in a map, but existing representations use discrete spatial sampling and typically require costly offline construction. We propose a continuous spatio-temporal MoD representation based on implicit neural functions that directly map coordinates to the parameters of a Semi-Wrapped Gaussian Mixture Model. This removes the need for discretization and imputation for unevenly sampled regions, enabling smooth generalization across both space and time. Evaluated on two public datasets with real-world people tracking data, our method achieves better accuracy of motion representation and smoother velocity distributions in sparse regions while still being computationally efficient, compared to available baselines. The proposed approach demonstrates a powerful and efficient way of modeling complex human motion patterns and high performance in the trajectory prediction downstream task. The code is publicly available at https://github.com/test-bai-cpu/nemo-map.

cs.RO

Spatiotemporal Calibration of Doppler Velocity Logs for Underwater Robots

The calibration of extrinsic parameters and clock offsets between sensors for high-accuracy performance in underwater SLAM systems remains insufficiently explored. Existing methods for Doppler Velocity Log (DVL) calibration are either constrained to specific sensor configurations or rely on oversimplified assumptions, and none jointly estimate translational extrinsics and time offsets. We propose a Unified Iterative Calibration (UIC) framework for general DVL sensor setups, formulated as a Maximum A Posteriori (MAP) estimation with a Gaussian Process (GP) motion prior for high-fidelity motion interpolation. UIC alternates between efficient GP-based motion state updates and gradient-based calibration variable updates, supported by a provably statistically consistent sequential initialization scheme. The proposed UIC can be applied to IMU, cameras and other modalities as co-sensors. We release an open-source DVL-camera calibration toolbox. Beyond underwater applications, several aspects of UIC-such as the integration of GP priors for MAP-based calibration and the design of provably reliable initialization procedures-are broadly applicable to other multi-sensor calibration problems. Finally, simulations and real-world tests validate our approach.

cs.RO