Abstract
In this work, we propose a haptic update control law that uses reaction torques to correct axial misalignment during robotic valve manipulation. Unlike vision-based estimates, which can be affected by calibration errors, occlusion, and uncertainty in the contact geometry, reaction torques arise directly from the physical interaction between the gripper and valve. A geometric relationship exists between the error (misalignment) vector and these torques. The primary aim of this work is to propose a stable controller exploiting this geometric property. Our control law is proven to be uniformly asymptotically stable. Simulations are performed for verification. Furthermore, we experimentally test the robustness of our method using a Kinova Gen3 robotic arm for initial misalignments ranging from $-15^\circ$ to $15^\circ$ at 3 different valve positions and report the resulting data distribution. The absolute value of the median misalignment across all 18 test cases is found to be within $2.46^\circ$ and that of reaction torques within $0.23\mathrm{Nm}$.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Amit Kumar, Sri Harsha Turlapati, Gautami Golani, Yang Lin, Ravi N. Banavar, Domenico Campolo. 2026-09-21. Robotic Valve Turning: Axial Misalignment Correction Using Reaction Torque Feedback. https://arxiv.org/abs/2609.24413
Cite the original work for its findings. Save a collection to share your selection of sources.