arXiv ScienceSearch

arXiv · 2609.17793

The Magnetic-Resonance-Based, Omni-Directional Hydrophone

Abstract

This study aims to improve the directional sensitivity of magnetic resonance hydrophone (MRH) methods and allow for detection and quantification of waves traveling at any angle relative to the MRI bore-axis. Doing so may better integrate MRH technology into transcranial focused ultrasound neuromodulation therapies. Existing MRH implementations only encode acoustic waves propagating along the MRI bore-axis, precluding use with wide aperture transducers or temporal skull windows. This study expands the MRH technique into a MR-based Omni-directional Hydrophone (MRbOH) that can quantify the magnitude pressure and phase of waves propagating at any angle. The MRbOH method formulates a system of equations around uniquely sensitized images that, when solved, introduce sensitivity to oblique acoustic waves. The method was tested experimentally in a gel phantom that was insonated at $0^o$, $45^o$, and $90^o$ relative to the MRI bore-axis. The method reconstructed pressure maps at all three angles of propagation, including features such as peak pressure, partial reflections, and beamwidth. The MRbOH method measured an average beamwidth of 16.2 mm while the hydrophone measured a beamwidth of 14.5 mm. Average hydrophone-measured pressure within a region of interest was 416.19 $\boldsymbol{\pm}$ 78.07 kPa. Average MRbOH measured pressure in the same region at $0^o$, $45^o$, and $90^o$, respectively, were: 285.5 $\boldsymbol{\pm}$ 49.5 kPa, 193.13 $\boldsymbol{\pm}$ 43.55 kPa, 194.7 $\boldsymbol{\pm}$ 47.38 kPa. In addition, the study presents and experimentally verifies a statistical noise model that predicted the mean with $R^2 = 0.85$, and standard deviation with $R^2 = 0.83$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nathan Thyberg, Davi Cavinatto, Katia Oler, Elijah Oxborrow, Hyrum Mangum, Steven P. Allen. 2026-09-15. The Magnetic-Resonance-Based, Omni-Directional Hydrophone. https://arxiv.org/abs/2609.17793

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Voxel-Matching NORDIC: Non-local patch formation by time-series similarity increases tSNR in high-resolution BOLD fMRI

Submillimeter functional magnetic resonance imaging (fMRI) based on blood-oxygenation-level-dependent (BOLD) signal enables the study of brain function at the submillimeter level, uncovering insights into fine-scale organisations like cortical layers and columns. However, its inherently low contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) often limit its reliability and applicability. Noise Reduction with Distribution Corrected Principal Components Analysis (NORDIC PCA) is a locally low-rank denoising algorithm that reduces thermal noise levels in BOLD fMRI in a local patch manner. However, local patches often contain a mixture of signals from multiple tissues that negatively affects the low-rank structure of the patches, which limits the denoising capabilities of the algorithm. We propose an alternative approach for patch formation by gathering similar non-local voxels, dubbed voxel-matching (VM) NORDIC. The results on submillimeter-resolution BOLD fMRI data indicate that VM-NORDIC effectively promotes the low rank of the patches by boosting signal redundancy, allowing for more efficient noise attenuation. Moreover, the method barely affects spatial smoothness due to the non-local voxel selection based on time-series similarity. In particular, VM-NORDIC outperforms standard NORDIC with default local patching (Standard-NORDIC) in terms of temporal SNR (tSNR) (~9-90% larger than Standard-NORDIC; ~23-250% larger than the original) and spatial smoothness estimates (~20% of the smoothness induced by Standard-NORDIC). These improvements are fundamental to improving the validity and precision of fMRI studies at submillimeter resolutions.

physics.med-ph

Computed Tomography Reconstruction Algorithm Using Markov Random Field Model

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available.

physics.med-ph

Charge Collection Efficiency in Air-Vented Plane-Parallel Ionisation Chambers at Ultra-High Dose Rates: A Self-Consistent Garfield++ Monte Carlo Model Including Space-Charge Effects and Ion Recombination

Ultra-high dose rate (UHDR) irradiation used in FLASH radiotherapy can lead to significant reductions in charge collection efficiency (CCE) in plane-parallel ionisation chambers (PPICs) due to enhanced ion recombination, while the high charge densities involved can also induce strong space-charge-induced electric-field distortions. To investigate these coupled effects, we extended the Garfield++ Monte Carlo particle-transport framework by implementing ion--ion recombination and self-consistent space-charge electric field calculations. The developed Monte Carlo model couples particle transport, electron attachment, recombination processes, and dynamic electric-field distortions. The implementation was validated against analytical and numerical models from the literature. Excellent agreement was obtained for the free electron fraction (FEF), CCE, induced current, and electric field evolution under UHDR conditions. The simulations show that space charge can locally increase the electric field by more than a factor of four or reduce it to nearly zero in some regions of the chamber. The results further suggest that the reduction of the CCE under UHDR conditions is mainly driven by the decrease of the FEF caused by electric-field-dependent electron attachment. This finding indicates that the complex problem of recombination under UHDR conditions may be largely governed by the evolution of the FEF, opening promising perspectives for the development of improved analytical models and real-time correction methods for ionisation chamber dosimetry under UHDR irradiation conditions. This work provides a flexible and self-consistent Monte Carlo framework for investigating recombination phenomena and improving dosimetry models for FLASH radiotherapy.

physics.med-ph