arXiv · 2609.16036
Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring
Abstract
We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 150 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80 percent across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (less than 5 percent) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid, Md. Tanzim Hossain, Md. Anwarul Islam, Md. Nishan Khan, Md. Misbah Khan, Labiba Faiza Karim, Jobaer Rahman, S M Hasibul Hoque, Rahnuma Shahrin Rista, Kamruzzaman Rumman, Md Arifur Rahman, Syed Md. Akram Hussain, Mohammad Ashrafuzzaman Khan, M. Monir Uddin. 2026-09-11. Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring. https://arxiv.org/abs/2609.16036
Cite the original work for its findings. Save a collection to share your selection of sources.