Abstract
Wi-Fi Fine Time Measurement (FTM) promises indoor localization by reusing access points (APs) already deployed for connectivity, but prior evaluations mostly use APs purpose-deployed or calibrated for ranging, leaving it unclear whether a production enterprise WLAN can provide useful localization without localization-specific infrastructure. We evaluate Wi-Fi round-trip time (RTT) localization on IllinoisNet, a live campus WLAN whose APs were placed for coverage and capacity. Using five commodity Android phones at 10 static locations across a 50 m x 30 m office floor spanning LOS, NLOS, and multipath conditions, weighted nonlinear least squares achieves a median error of 1.21 m and a 90th-percentile error of 2.68 m, with no AP replacement, repositioning, or ranging calibration. Residuals vary in magnitude and sign across APs and propagation conditions, suggesting a single global correction is insufficient and motivating AP-aware software calibration rather than new localization-specific infrastructure.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Enguang Fan, Binh Minh Tran, Klara Nahrstedt. 2026-09-12. Meter-Level Wi-Fi RTT Localization on a Production Enterprise WLAN. https://doi.org/10.1145/3795866.3844758