arXiv ScienceSearch

arXiv · 2609.09415

Intrinsic time resolution of a hexagonal BC404 scintillator: A Monte Carlo study of interaction geometry and optical reflectivity

Abstract

Time resolution is an important parameter in particle detectors, as it determines their ability to distinguish between two temporally separated events. It can be decomposed into electronic and intrinsic contributions, the latter being influenced by scintillation, optical transport, detector geometry, particle type and energy, and the sensitive area of the photosensor. In this work, a Monte Carlo simulation based on Geant4 is used to investigate the intrinsic time resolution of a hexagonal BC404 plastic scintillator. The analysis includes the evaluation of the optical-photon distribution over the hexagonal surfaces and the characterization of the intrinsic time resolution for different interaction configurations. The intrinsic time resolution is investigated using muons as cosmic-ray proxies with energies ranging from 4~GeV to 1~TeV. In addition, the effect of surface reflectivity on optical-photon transport and timing performance is studied for reflectivities ranging from 0\% to 100\%. The results show that the intrinsic time resolution exhibits little dependence on the incident muon energy, while a clear dependence on the interaction position is observed. Furthermore, although the number of detected photons varies with the interaction position and surface reflectivity, the intrinsic time resolution is not solely determined by photon statistics, indicating that optical transport and geometrical effects play an important role in the timing performance. Across the investigated configurations, intrinsic time resolutions ranging from approximately 15 to 100~ps are obtained. These findings highlight the importance of the interaction position, optical transport, photon statistics, and surface reflectivity in determining the timing performance of hexagonal plastic scintillators and provide guidance for the optimization of their optical properties and geometry for timing-sensitive applications.

Explore related subjects

Keep this discovery

BibTeXRIS

C. H. Zepeda-Fernández, L. F. Rebolledo-Herrera, E. Moreno Barbosa. 2026-09-08. Intrinsic time resolution of a hexagonal BC404 scintillator: A Monte Carlo study of interaction geometry and optical reflectivity. https://arxiv.org/abs/2609.09415

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det