Techno-Economic Boundary Analysis of Small Modular Reactor Cogeneration for Hyperscale Data Center IT and Cooling Loads

Abstract

Hyperscale data centers are adding firm, high-utilization demand faster than grids can serve it, renewing interest in colocating them with small modular reactors. Such a plant could earn revenue in two ways, selling low-carbon power and diverting steam to absorption chillers that serve a cooling load accounting for 20-40% of facility electricity use, but neither revenue stream has been priced across the conditions that must coincide. Here we co-optimize reactor dispatch, steam extraction, absorption cooling and grid exchange hourly for a 200 MW$_\mathrm{e}$ data center in the Electric Reliability Council of Texas (ERCOT) region, across 109 runs spanning capital, market, policy, financing and cooling efficiency. At 2023 mid-range reactor capital, the nuclear configurations cost 49-62% more than grid supply even with the Section 45Y production tax credit. The viable region opens near \$5,000 kW$_\mathrm{e}^{-1}$, and nth-of-a-kind capital makes them 77-89% cheaper in 2023, though between parity and 34% more expensive in the low-price 2024 market. A carbon price of \$53-64 tCO$_2^{-1}$ closes the mid-range gap under hourly export crediting. Absorption cooling is dispatched in response to hourly electricity prices and supplies 38% of annual cooling, at an added cost of \$9.2 million yr$^{-1}$ relative to the reactor-only plant; that gap closes at an installed absorption cost of \$60 kW$_\mathrm{c}^{-1}$ at baseline efficiency and \$570 kW$_\mathrm{c}^{-1}$ on a legacy-efficiency campus, against surveyed commercial prices of \$450-1,200 kW$_\mathrm{c}^{-1}$. Together these results delineate the capital, market and policy conditions under which colocated reactor cogeneration is competitive with grid procurement, and the range over which each condition moves the outcome.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Honglin Li, Buxin She, Jie Zhang. 2026-08-11. Techno-Economic Boundary Analysis of Small Modular Reactor Cogeneration for Hyperscale Data Center IT and Cooling Loads. https://arxiv.org/abs/2608.10999

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Cooperative Multi-Agent Assignment over Stochastic Graphs via Constrained Reinforcement Learning

Constrained multi-agent reinforcement learning offers the framework to design scalable and almost surely feasible solutions for teams of agents operating in dynamic environments to carry out conflicting tasks. We address the challenges of multi-agent coordination through an unconventional formulation in which the dual variables are not driven to convergence but are free to cycle, enabling agents to adapt their policies dynamically based on real-time constraint satisfaction levels. The coordination relies on a light single-bit communication protocol over a network with stochastic connectivity. Using this gossiped information, agents update local estimates of the dual variables. Furthermore, we modify the local dual dynamics by introducing a contraction factor, which lets us use finite communication buffers and keep the estimation error bounded. Under this model, we provide theoretical guarantees of almost sure feasibility and corroborate them with numerical experiments in which a team of robots successfully patrols multiple regions, communicating under a time-varying ad-hoc network.

eess.SY

Which Top Energy-Intensive Manufacturing Countries Can Compete in a Renewable Energy Future?

In a world increasingly powered by renewables and aiming for greenhouse gas-neutral industrial production, the future competitiveness of todays top manufacturing countries is questioned. This study applies detailed energy system modeling to quantify the Renewable Pull, an incentive for industry relocation exerted by countries with favorable renewable conditions. Results reveal that the Renewable Pull is not a cross-industrial phenomenon but strongly depends on the relationship between energy costs and transport costs. The intensity of the Renewable Pull varies, with China, India, and Japan facing a significantly stronger effect than Germany and the United States. Incorporating national capital cost assumptions proves critical, reducing Germanys Renewable Pull by a factor of six and positioning it as the second least affected top manufacturing country after Saudi Arabia. Using Germany as a case study, the analysis moreover illustrates that targeted import strategies, especially within the EU, can nearly eliminate the Renewable Pull, offering policymakers clear options for risk mitigation.

eess.SY

Certifying Frequency Stability for Systems with Line Dynamics and Heterogeneous Bus Dynamics

This work presents a framework for certifying small-signal frequency stability of a power system with line dynamics and heterogeneous bus dynamics. This framework can certify the stability of systems which include synchronous generators, synchronous condensers, and converter-interfaced resources with a wide range of controls. Moreover, it can do so without detailed or precise knowledge of the network topology. With this framework, we also provide a detailed analysis of how proportional-derivative (PD) droop can improve the stability margin of the frequency response. The stability certificates presented in this work, which extend prior results by incorporating line dynamics, provide insight into how the control parameters for different units in the system impact the overall frequency stability. While damper windings have long been understood to improve the frequency synchronization between machines, the dynamics of the damper windings are complex, making them difficult to analyze. To address this gap, this paper derives a novel reduced-order model of the damper windings in the form of a derivative droop term. Moreover, we show that derivative droop terms used in grid-forming (GFM) control can be understood as a form of damper winding emulation. Our analytical stability conditions highlight the importance of damper windings (or their emulation) in facilitating frequency synchronization and suppressing unstable interactions between GFM converters. These results are validated with electromagnetic-transient (EMT) simulation.

eess.SY