arXiv ScienceSearch

arXiv · 2606.18614

A Search for Effects of Cosmic Rays with Multi-scale Entropy Metrics

Abstract

We report a comparison of frequency fluctuations in oven-controlled quartz bulk-acoustic-wave oscillators operated above ground and one kilometre underground in a low-muon-background environment. The experiment is motivated by the possibility that cosmic rays and other ionizing-radiation backgrounds produce rare, impulsive energy-deposition events that perturb high-Q mechanical resonators and appear as intermittent, non-Gaussian structure in oscillator frequency noise. Conventional power spectral density and Allan-deviation analyses show no statistically compelling separation between the two environments over the explored timescales. In contrast, multi-scale sample entropy and its modified form reveal a pronounced divergence, with the underground data exhibiting increased predictability over a broad range of effective integration times. This result identifies a change in the temporal structure of the oscillator fluctuations that is largely hidden from standard second-order frequency-stability metrics. We therefore propose multi-scale sample entropy as a new diagnostic for frequency control and timing, complementary to Allan deviation and spectral analysis, with particular sensitivity to intermittent structure, non-stationary contributions, and rare-event contamination. The observed entropy separation also provides evidence that the above-ground cosmic-ray environment influences oscillator frequency fluctuations, suggesting that radiation-linked disturbances may contribute to the stochastic behaviour of precision mechanical oscillators. These findings introduce an entropy-based methodology for oscillator metrology and provide a practical tool for future fundamental-physics experiments using cryogenic resonant sensors, where rare-event backgrounds and poorly understood low-frequency noise can limit sensitivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

William M. Campbell, Ben T. McAllister, Eugene N. Ivanov, Michael E. Tobar, Mehran Mossammaparast, Mike Sawicki, Maxim Goryachev. 2026-06-17. A Search for Effects of Cosmic Rays with Multi-scale Entropy Metrics. https://arxiv.org/abs/2606.18614

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det