Quantitative comparison of heat flow, guarded-heater and AC Harman methods for thermoelectric module efficiency

Abstract

The evaluation of thermoelectric conversion efficiency remains challenging owing to the lack of internationally standardized measurement protocols. Commonly used techniques -including the heat flow, guarded heater, and AC Harman methods-differ fundamentally in their operating principles and sensitivity to heat losses. In this study, we benchmark three module-level efficiency measurement techniques -the heat-flow, guarded heater, and AC Harman methods- using commercial Bi2Te3-based modules with different module architectures. The conversion efficiencies obtained using the heat flow and guarded heater methods showed closely consistent central values and similar temperature-dependent trends over the investigated range. In contrast, the efficiency derived using the AC Harman method was systematically lower by approximately 16 % to 30 %, depending on the module architecture. Steady-state finite-element calculations of heat conduction and radiation indicated that the open thermal boundary condition used in the Harman configuration produces module-architecture-dependent internal temperature distributions and effective temperature differences, consistent with the experimentally observed trend. These results demonstrate that module-level efficiency estimated using the AC Harman method can be affected by nonideal thermal environments and emphasize the necessity of accounting for radiative and substrate-related heat losses. Nevertheless, the AC Harman method remains useful for rapid performance screening, provided that its module- and boundary-condition-dependent systematic bias is appropriately considered. Our results provide a quantitative benchmark for major measurement techniques and support the development of best practices, method-selection guidelines, and future methodological standardization in module-level thermoelectric metrology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kenjiro Okawa, Yasutaka Amagai, Norihiko Sakamoto, Nobu-Hisa Kaneko. 2026-08-03. Quantitative comparison of heat flow, guarded-heater and AC Harman methods for thermoelectric module efficiency. https://doi.org/10.1016/j.applthermaleng.2026.132839

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Thermoreflectance-Based Techniques for Micro- and Nanoscale Thermophysical Property Measurements: Principles, Methods, and Recent Advances

As semiconductor devices shrink toward the nanoscale, heat transport and thermal-energy-storage behavior in materials and interfaces become increasingly dependent on length scale, structure, and interfaces. Accurate characterization of thermophysical properties, including thermal conductivity, interfacial thermal conductance, and volumetric heat capacity, is therefore essential for functional-material design and thermal management of advanced electronic devices. Photothermal thermoreflectance techniques provide noncontact measurements with high spatial and temporal resolution and a broad measurement range, making them important tools for micro- and nanoscale thermophysical characterization. This review examines the physical principles and technical characteristics of transient thermoreflectance (TTR), time-domain thermoreflectance (TDTR), frequency-domain thermoreflectance (FDTR), steady-state thermoreflectance (SSTR), spatial-domain thermoreflectance (SDTR), and the square-pulsed source (SPS) method. A unified heat-diffusion framework is established to compare these methods in terms of parameter sensitivity, measurement uncertainty, and applicability. Representative applications illustrate their suitability for low-thermal-conductivity materials, anisotropic films, crystalline materials, and multilayer heterostructures, as well as their complementary capabilities for characterizing thin-film thermal conductivity, interfacial thermal conductance, and in-plane/cross-plane heat transport. Finally, emerging directions are discussed, including ultrahigh spatiotemporal resolution, multiphysics coupling, in-line industrial inspection, intelligent data processing, and natural-language-driven analysis.

physics.app-ph

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph