arXiv ScienceSearch

arXiv · 2605.09835

Environmental $\gamma$-Ray Flux in Hall C at LNGS and Its Correlation with Radon Activity

Abstract

We report a comprehensive measurement of the environmental $\gamma$-ray flux in Hall C of the Gran Sasso National Laboratory. A spatial mapping of the radiation was carried out using a high-purity germanium detector mounted on a movable cart and deployed at eight locations within the hall. The detector response function and full-energy-peak efficiencies were determined through Geant4 simulations validated with calibrated $\gamma$-ray sources, with particular attention devoted to the efficiency modeling and associated systematic uncertainties. In the energy range of 57-2800 keV, the average $\gamma$-ray flux is measured to be $(\mathrm{0.46} \pm \mathrm{0.06}_{stat} \pm \mathrm{0.03}_{syst})$ $\mathrm{cm}^{-2}$ $\mathrm{s}^{-1}$. The radon level was monitored for about a month using a radon detector mounted on the same cart, and a clear correlation is observed between the environmental $\gamma$-ray rate and the ambient radon concentration, consistent with the short-lived daughters of $^{222}\mathrm{Rn}$. This result represents the first high-precision and efficiency-corrected mapping of the $\gamma$-ray flux in Hall C, substantially improving its radiological characterization and providing key input for future rare-event experiments operating in this hall.

Explore related subjects

Keep this discovery

BibTeXRIS

L. Luzzi, R. Santorelli, G. Zuzel, P. Agnes, D. Cano-Ott, C. Ghiano, M. Laubenstein, T. Mroz, V. Pesudo Fortes, J. Plaza del Olmo, G. Vera Díaz. 2026-05-11. Environmental $\gamma$-Ray Flux in Hall C at LNGS and Its Correlation with Radon Activity. https://doi.org/10.1103/rm39-mmyk

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det