Characterisation of the Thermoflow due to the Dry Nitrogen Flushing Scheme in the ATLAS Inner Tracker using Computational Fluid Dynamics

Abstract

The planned High Luminosity upgrade to the Large Hadron Collider at CERN aims to increase the instantaneous luminosity peak to about 7.5 x 10^{34} cm^{-2}s^{-1}. The ATLAS detector will be extensively re-designed to meet the challenges of this upgrade. This paper focuses on the use of computational fluid dynamics to characterise the thermoflow in order to model the dry nitrogen flushing scheme in the Common Environmental Monitoring and Interlock System for the ATLAS Inner Tracker as part of the upgrade process. The Technical Design Report considers the possibility for the bi-phase CO2 coolant temperature to drop to as low as -55 degrees C in the case of a fault. The specification for the highest Relative Humidity within the ITk volume is therefore equivalent to a dew point temperature at or below -60 degrees C in order to prevent condensation which could damage the detector electronics. The design accommodates for humidity monitoring to detect the onset of such events and dry nitrogen flushing to remove moisture. Therefore, it is important to thoroughly understand all consequences of atmospheric air ingress due to air-leaks and/or air-ingress from the outlets due to the over-pressure. The computational fluid dynamics model presented in this study was used to provide quantitative and qualitative insight into the various operational and failure conditions, informing engineering design changes to optimise the flushing scheme and ensure that the ITk remains dry and within the design specification of the acceptable dew point range.

Explore related subjects

Keep this discovery

BibTeXRIS

Muaaz Bhamjee, Matthew Connell, Simon Connell, Emmanuel Igumbor, Lerothodi Leeuw, Pedro Mafa, Marco Oriunno, Marcel Vreeswijk. 2026-05-08. Characterisation of the Thermoflow due to the Dry Nitrogen Flushing Scheme in the ATLAS Inner Tracker using Computational Fluid Dynamics. https://arxiv.org/abs/2605.08331

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det