arXiv ScienceSearch

arXiv · 2604.22258

Protect the Brain When Treating the Heart: Feasibility of 2.5D U-Net for Real-Time Gaseous Microemboli Detection

Abstract

Gaseous microemboli (GME) represent a common complication of cardiac structural interventions across both surgical and transcatheter approaches. Intraoperative transesophageal echocardiography (TEE) represents a convenient methodology to monitor and visualize the presence of circulating GME. However, their detection and quantification are far from trivial due to operator-dependent view, high velocity, and objects with similar structure in the background. Here, we propose a feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data. We applied and tested such an architecture on a pilot dataset of eight TEE recordings ($60$ fps, $600\times 800$ pixels) from eight different patients undergoing cardiac surgery, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures. Under leave-one-patient-out cross-validation, the selected model achieved strong detection performance under a three-pixel radius-tolerant grace-zone evaluation, with a precision of 92.55\% and recall of 80.54\%, corresponding to radius-tolerant Intersection over Union (IoU) and Dice coefficients of 73.95\% and 84.13\%, respectively. Complementarily, strict pixel-based segmentation metrics were also computed, yielding an IoU of 41.74\% and a Dice coefficient of 57.98\%. The selected model achieved an average inference time of $0.12 s$ per batch on the tested hardware. To assess specificity on unseen data, we additionally evaluated the model on an external GME-negative TEE dataset, where it produced predominantly empty or near-empty masks, indicating a low rate of spurious detections. These results support the technical feasibility of real-time GME segmentation.

Explore related subjects

Keep this discovery

BibTeXRIS

Andrea Angino, Ken Trotti, Diego Ulisse Pizzagalli, Rolf Krause, Tiziano Torre, Stefanos Demertzis. 2026-04-24. Protect the Brain When Treating the Heart: Feasibility of 2.5D U-Net for Real-Time Gaseous Microemboli Detection. https://arxiv.org/abs/2604.22258

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG