arXiv ScienceSearch

arXiv · 2602.12836

Measurements of absolute gamma-ray energies using an ultra-high energy resolution magnetic microcalorimeter

Abstract

We present new measurements of 27 gamma ray energies ranging from 14 keV to 136 keV, obtained using high-energy-resolution magnetic microcalorimeters for energy-dispersive spectrometry. The spectrometer has eight pixels and achieves an energy resolution between 15 and 30 eV across the entire energy range. It faces a cryogenic source sampler with four movable sources. Each source contains a mixture of radionuclides, including Yb-169 and Co-57 used to calibrate the spectrometer and correct its non-linearity. The gamma-ray energies, emitted through the decay of Co-57, Cd-109, Ba-133, Gd-153, Eu-154, Eu-155, Yb-169, Tm-170, Pb-210, Np-239, Am-241 and Am-243, have been reassessed. The lowest absolute uncertainty achieved is 0.13 eV at 105.3 keV, which corresponds to a relative uncertainty of 1.3 ppm. Of the 27 measured gamma rays, the uncertainties of 19 energies were improved with respect to the available literature: 10 by a factor of 5 and 4 by more than one order of magnitude. Good agreement is observed with energies obtained elsewhere by wavelength-dispersive spectrometry. This work significantly improves upon previously reported gamma energies obtained by energy-dispersive spectrometry using semiconductor detectors, thanks to the ultra-high energy resolution of magnetic microcalorimeters.

Explore related subjects

Keep this discovery

BibTeXRIS

Matias Rodrigues, Mostafa L. Zahir, Martin Loidl, Lucille Chambon, Quentin Drenne, Michael Müller, Sebastian Kempf, Etienne Nigron, Ferid Haddad. 2026-02-13. Measurements of absolute gamma-ray energies using an ultra-high energy resolution magnetic microcalorimeter. https://arxiv.org/abs/2602.12836

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det