arXiv ScienceSearch

arXiv · 2601.12553

Design Optimization of Triple Gas Electron Multiplier for Superior Gain and Reduced Ion Backflow

Abstract

Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron Multiplier (GEM) has emerged as one of the most widely adopted MPGD technologies. Despite their widespread adoption, GEM detectors based on the conventional bi-conical hole geometry do not always achieve optimal performance, particularly in maximizing effective gain while suppressing ion backflow. One of the primary factors limiting a GEM's performance is ion backflow. The accumulation and gradual discharge of these ions might alter the local electric field, resulting in a temporary dead time and complicating responses to subsequent events. These limitations pose challenges for applications requiring high precision and stable long-term operation. In this work, we address these issues by investigating modified GEM geometries designed to enhance gain performance and reduce ion backflow, thereby improving overall detector performance. The current study investigates geometric optimization strategies for a triple-GEM detector to enhance performance, mitigate ion backflow, and augment gain. The detector structures were designed using the ANSYS Mechanical APDL, and the associated electrostatic field configurations were computed using the ANSYS Maxwell. A thorough investigation of gain and ion backflow calculations was carried out when the generated field maps were interfaced with Garfield$^{++}$. The potential enhancements in detector efficiency and stability that the proposed modifications to the GEM foil geometry offers a valuable insights for the design of next-generation gaseous detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sachin Rana, Md. Kaosor Ali Mondal, Poojan Angiras, Amal Sarkar. 2026-01-18. Design Optimization of Triple Gas Electron Multiplier for Superior Gain and Reduced Ion Backflow. https://arxiv.org/abs/2601.12553

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det