SPIDER, a Waveform Digitizer ASIC for picosecond timing in LHCb PicoCal

Abstract

We present the architecture, design and first test results of SPIDER, the first prototype of a TSMC CMOS 65 nm ASIC designed for the time measurement path of LHCb Electromagnetic Calorimeter after LS4 Upgrade. The main requirements for the readout of this detector are a time resolution below 15 ps rms above 5 GeV, and a channel occupancy up to 30\% (12 Mevent/s). The first prototype called SPIDER\_V0 is a 2-channel waveform digitizer locked on the LHC clock allowing precise time reconstruction by digital algorithms. The architecture is based on 2 DLLs in series controlling respectively the phase of the sampling window and the sampling frequency, the latter covering the range between 2 and 20 GS/s. Each self-triggering channel houses 8 banks of 32 analog memory cells and a massively parallel Wilkinson ADC for conversion at 5 GHz over 10 bits with a maximal conversion time of 200 ns. SPIDER targets not only LHCb, but all fast detectors mounted on current and future accelerators. Its sampling frequency can indeed be adjusted to different signal risetimes. Its main frequency of 40 MHz could even be eventually locked to another value by modifying only one of the DLLs in the chip design.

Explore related subjects

Keep this discovery

BibTeXRIS

Ludovic Alvado, Nicolas Arveuf, Edouard Bechetoille, Guillaume Blanchard, Dominique Breton, Baptiste Joly, Laurent Leterrier, Jihane Maalmi, Samuel Manen, Hervé Mathez, Christophe Sylvia, Philippe Vallerand, Richard Vandaele. 2025-12-19. SPIDER, a Waveform Digitizer ASIC for picosecond timing in LHCb PicoCal. https://arxiv.org/abs/2512.17355

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det