Manganese-based macrocyclic chelates as novel MRI contrast agents: In vivo imaging in a porcine model

Abstract

Objectives: Mn-based MRI contrast agents (MBCAs) have recently been proposed as alternatives to the currently used class of Gd-chelates. Unlike Gd, Mn is an endogenous paramagnetic metal with known biochemical pathways in the human body for excretion and metal regulation, which may alleviate the raised concerns about the safety of existing GBCAs. The aim of this study was to investigate the distribution, kinetics and image enhancement properties of a class of novel Mn-based macrocyclic chelates in a porcine model. Methods: Macrocyclic MBCAs, AH114608, GEH300017 and GEH200486, were tested and compared to gadoterate meglumine. Twelve female adult pigs were divided into four groups (n=3 for each CA). At 3 T MRI, T1 relaxometry analysis were measured longitudinally in multiple organs at five timepoints 30 minutes apart. CA kinetics was estimated from analysis of plasma CA concentrations by ICP-OES. Results: All four CAs exhibited T1-enhancing properties in the blood pool with GEH200486 having the largest increase in T1 relaxation rate (R1), GEH300017 and gadoterate meglumine having similar R1 increase and AH114608 a lower peak R1 change. A persistent increase in liver, kidney and myocardium R1 was observed with AH114608. To a lesser extent, a persistent increase of liver enhancement was also observed in T1-weighted images for GEH300017 and GEH200486 compared to gadoterate meglumine. All four CAs had similar bi-exponential plasma kinetics characterized by a rapid distribution phase and a slower elimination phase. Discussion: We have identified MBCA candidates with predominantly renal clearance and comparable efficacy in terms of vascular T1 relaxation, and comparable to the reference GBCA. The T1-enhancing properties of these novel Mn macrocyclic CAs can be used with routine clinical protocols and could be potentially utilised as an alternative to GBCAs for contrast-enhanced MRI procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pål B. Marthinsen, Tuva R. Hope, Wibeke Nordhøy, Deirdre B. Cassidy, Adrian P. L. Smith, Paul M. Evans, Atle Bjørnerud. 2025-11-25. Manganese-based macrocyclic chelates as novel MRI contrast agents: In vivo imaging in a porcine model. https://arxiv.org/abs/2511.20358

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Voxel-Matching NORDIC: Non-local patch formation by time-series similarity increases tSNR in high-resolution BOLD fMRI

Submillimeter functional magnetic resonance imaging (fMRI) based on blood-oxygenation-level-dependent (BOLD) signal enables the study of brain function at the submillimeter level, uncovering insights into fine-scale organisations like cortical layers and columns. However, its inherently low contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) often limit its reliability and applicability. Noise Reduction with Distribution Corrected Principal Components Analysis (NORDIC PCA) is a locally low-rank denoising algorithm that reduces thermal noise levels in BOLD fMRI in a local patch manner. However, local patches often contain a mixture of signals from multiple tissues that negatively affects the low-rank structure of the patches, which limits the denoising capabilities of the algorithm. We propose an alternative approach for patch formation by gathering similar non-local voxels, dubbed voxel-matching (VM) NORDIC. The results on submillimeter-resolution BOLD fMRI data indicate that VM-NORDIC effectively promotes the low rank of the patches by boosting signal redundancy, allowing for more efficient noise attenuation. Moreover, the method barely affects spatial smoothness due to the non-local voxel selection based on time-series similarity. In particular, VM-NORDIC outperforms standard NORDIC with default local patching (Standard-NORDIC) in terms of temporal SNR (tSNR) (~9-90% larger than Standard-NORDIC; ~23-250% larger than the original) and spatial smoothness estimates (~20% of the smoothness induced by Standard-NORDIC). These improvements are fundamental to improving the validity and precision of fMRI studies at submillimeter resolutions.

physics.med-ph

Computed Tomography Reconstruction Algorithm Using Markov Random Field Model

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available.

physics.med-ph

Charge Collection Efficiency in Air-Vented Plane-Parallel Ionisation Chambers at Ultra-High Dose Rates: A Self-Consistent Garfield++ Monte Carlo Model Including Space-Charge Effects and Ion Recombination

Ultra-high dose rate (UHDR) irradiation used in FLASH radiotherapy can lead to significant reductions in charge collection efficiency (CCE) in plane-parallel ionisation chambers (PPICs) due to enhanced ion recombination, while the high charge densities involved can also induce strong space-charge-induced electric-field distortions. To investigate these coupled effects, we extended the Garfield++ Monte Carlo particle-transport framework by implementing ion--ion recombination and self-consistent space-charge electric field calculations. The developed Monte Carlo model couples particle transport, electron attachment, recombination processes, and dynamic electric-field distortions. The implementation was validated against analytical and numerical models from the literature. Excellent agreement was obtained for the free electron fraction (FEF), CCE, induced current, and electric field evolution under UHDR conditions. The simulations show that space charge can locally increase the electric field by more than a factor of four or reduce it to nearly zero in some regions of the chamber. The results further suggest that the reduction of the CCE under UHDR conditions is mainly driven by the decrease of the FEF caused by electric-field-dependent electron attachment. This finding indicates that the complex problem of recombination under UHDR conditions may be largely governed by the evolution of the FEF, opening promising perspectives for the development of improved analytical models and real-time correction methods for ionisation chamber dosimetry under UHDR irradiation conditions. This work provides a flexible and self-consistent Monte Carlo framework for investigating recombination phenomena and improving dosimetry models for FLASH radiotherapy.

physics.med-ph