arXiv ScienceSearch

arXiv · 2511.19938

Topological Data Analysis of Northern Hemisphere SLP Anomalies: Identifying and Tracking the Structural Skeleton of Atmospheric Pressure Systems

Abstract

We propose a novel framework based on Topological Data Analysis (TDA) to identify and track cyclonic and anticyclonic structures in the Northern Hemisphere. Using persistent homology applied to seven decades of daily sea-level pressure anomalies (1948--2023), we represent the atmospheric field as a cubical complex and compute sublevel- and superlevel-set filtrations. This approach allows us to identify 1-dimensional topological features (1-holes) that correspond to coherent pressure systems, which we term 1-cyclones and 1-anticyclones. The structural intensity of these features is quantified through their topological depth, while their dynamical evolution is followed using an optimal matching procedure based on the Wasserstein distance between consecutive persistence diagrams. Our results reveal robust seasonal patterns characterized by winter maxima and summer minima in total persistence, frequency, and spatial extent. We show that cyclonic activity is topologically more fragmented and intense, consistent with the seasonal deepening of the Icelandic Low, whereas anticyclones exhibit a heavier long-duration tail associated with persistent blocking episodes. Crucially, we demonstrate that TDA metrics can differentiate between distinct dynamical regimes of atmospheric blocking, distinguishing the quasi-stationary, ``frozen'' topology of the 2003 European heatwave from the more volatile and unstable configuration of the 2012 cold spell. Compared to classical geometric tracking algorithms, this framework provides an objective, multiscale, and noise-robust characterization of the atmospheric skeleton, offering a unified mathematical description of the organization and stability of mid-latitude circulation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Himanshu Yadav, Gisela D. Charó, Davide Faranda. 2026-07-30. Topological Data Analysis of Northern Hemisphere SLP Anomalies: Identifying and Tracking the Structural Skeleton of Atmospheric Pressure Systems. https://arxiv.org/abs/2511.19938

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Surface Stokes drift from compact drifting wave buoys

Surface Stokes drift depends strongly on the energy and directions of short waves, which are incompletely resolved by routine wave observations. We derive surface Stokes drift vectors from wave measurements collected by compact drifting buoys during three deployments in the North-East Atlantic and the Alboran Sea. The calculation uses vertical-acceleration spectra and first directional Fourier moments, which describe the mean wave direction and directional concentration at each frequency; it accounts for the Doppler shift caused by buoy motion relative to the water and adds a calibrated high-frequency tail above an intrinsic frequency of 0.7 Hz. Across 13,139 records, the median estimated speed is 0.081 m/s at a median wind speed of 6.8 m/s. Over the measured band of 0.04-1 Hz, accounting for wave directions reduces the magnitude by a median 39% relative to the unidirectional assumption. The median ratio of the parameterised tail magnitude above 0.7 Hz to the total estimated magnitude is 0.37. Comparisons with WAVEWATCH III and Copernicus Marine MFWAM show strong covariation and similar wind-dependent differences from the buoy-derived estimates. On the station-matched sample from the two Atlantic deployments, WAVEWATCH III directional spectra indicate that these differences within the compared band arise mainly from spectral levels rather than from net directional reduction. The observations provide constraints for model evaluation; the contribution of the unresolved short waves remains sensitive to the assumed spectral tail and its directional spreading.

physics.ao-ph

Unreported large errors from two PAMGuard three-dimensional localizers of whale calls

Confidence intervals of location (CIL) of calling marine mammals, derived from time-differences-of-arrival (TDOA) between receivers, depend on errors of TDOAs, receiver location, clocks, sound speeds, and location method. When these errors are minuscule, simulations yield small errors of PAMGuard's 3D simplex localizer when click sounds of beaked and sperm whales originate in a 1000 x 1000 x 1000 $\mbox{m}^3$ region using five receivers having horizontal and vertical separations of 1000 m and 150 m respectively. Realistic uncertainties of sound speed up to $\pm 10$ m/s lead to errors up to $10^{14}$ m. With clocks maintained by atomic standards and common practice of correcting TDOA from synchronization measurements at the start and end of an experiment, errors of location are up to $10^{4}$ m. Errors up to $10^2$ and $10^3$ m are found when the receiver's locations are uncertain within 10 and 40 m respectively. Errors of PAMGuard's 3D hyperbolic localizer are almost independent of the above uncertainties, yielding errors of location up to about $10^4$ m even when simulated errors are minuscule. Causes of PAMGuard's 3D location errors are unknown. These algorithms are briefly compared to another method designed to yield a reliable CIL.

physics.ao-ph

Tropospheric Ozone Formation Potential and Related Design Considerations for Radiative Coolers

Recently, radiative coolers have been widely explored for reducing cooling loads or lowering temperatures in buildings, and at urban scales as a heat-mitigation measure. However, the potential impacts of radiative cooler deployment on the chemical composition of the atmosphere remain largely unexplored. A defining feature of recently-designed radiative coolers is their high ultraviolet (UV) reflectance, which is required for sub-ambient cooling under strong sunlight. Yet, wide adoption of such UV-reflective radiative coolers could substantially increase the UV actinic flux in the atmosphere above. This, in turn, may affect tropospheric ozone concentrations, particularly in urban atmospheres with high NOx concentrations. Here, as a case study, we use a 0-dimensional photochemical box model, constrained by field measurements of meteorological conditions and chemical concentrations in the urban environment of Houston, Texas, to explore the potential impact of the widespread use of UV-reflective radiative coolers on ozone concentrations. Our calculations show that complete deployment of radiative coolers may increase tropospheric ozone levels by as much as 30% during specific meteorological conditions in Houston. Informed by the wavelength-dependent modelling results, we propose specific designs, namely pigmented radiative coolers with different UV reflectances, and UV-absorptive visible-reemitting fluorescent radiative coolers, that could minimize negative ozone formation while retaining appreciable cooling performance. Our results motivate further study on the effects of widespread deployment of radiative cooling designs like superwhite roof paints on air quality, and materials that simultaneously minimize adverse photochemical impact and maximize cooling performance.

physics.ao-ph