arXiv ScienceSearch

arXiv · 2511.16677

Electromagnetic transients and failed upward leaders observed during lightning activity in an onshore wind farm

Abstract

At a wind farm in Croatia, lightning activity is monitored across the entire site using a lightning location system, and on a single wind turbine equipped with a Rogowski-coil-based current measurement system and a high-speed camera, all independently GPS-synchronized. In addition to recording lightning flash currents on the monitored turbine, the system is frequently triggered by electromagnetic disturbances caused by nearby lightning flashes. These include direct flashes to two neighboring turbines that share the same cable connection to the substation and have interconnected grounding systems with buried bare conductor, as well as cloud-to-ground flashes to soil near cable routes, where the resulting electromagnetic fields couple onto the cables, causing surges to propagate to the monitored turbine. The camera occasionally captures failed upward connecting leaders from the monitored turbine during these lightning events. This paper presents three cases of flashes to two neighboring wind turbines and two cases of cloud-to-ground flashes to nearby soil, all of which induced electromagnetic transients that propagated to the monitored turbine. Failed upward connecting leaders were observed in some of these cases. This paper provides observational analysis, providing Rogowski measurements of electromagnetic disturbances and failed leader currents, complemented by high-speed camera and lightning location system data.

Explore related subjects

Keep this discovery

BibTeXRIS

Franjo Vukovic, Bozidar Filipovic-Grcic, Nina Stipetic, Bojan Franc. 2025-11-09. Electromagnetic transients and failed upward leaders observed during lightning activity in an onshore wind farm. https://doi.org/10.1016/j.epsr.2025.112216

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det