arXiv ScienceSearch

arXiv · 2510.19775

Interpretable machine learning for identifying individual-specific cardiogram signatures

Abstract

This study investigates cardiogram-based biometric identification as a physiological authentication problem, focusing on the discriminative capacity of electrocardiogram (ECG) and impedance cardiogram (ICG) features and their robustness to emotional variability. A total of 29 features spanning four domains (temporal, amplitude, slope, and morphological) are evaluated using random forest (RF) models combined with multiple interpretability methods. Features derived from ECG and ICG rank consistently among the top 10 most important by Gini importance, permutation importance, and Shapley additive explanations (SHAP) values, with ECG-derived QRS descriptors occupying the highest positions. In parallel, BCX features derived from ICG provide complementary information, although their stability across methods is lower. Correlation analysis reveals substantial multicollinearity, where the RF distributes and diminishes importance across highly correlated pairs, confirming reduced independent contributions. Statistical analysis identifies 14 features that differ significantly between baseline and anger, without a clear pattern by domain. Feature selection with recursive feature elimination and genetic algorithms converges on a subset (12 features) that attains accuracy within 1% of the full set (99%), improving efficiency in storage and computation. Complementary analyses indicate that individual differences are primarily encoded in ECG features describing QRS amplitude, slope, morphology, and duration, with the first three remaining stable between baseline and anger, and duration being the only selected QRS feature that changes significantly. BCX amplitude features provide supportive but less stable discriminatory cues. More broadly, the proposed framework may help distinguish stable person-related characteristics, such as identity and personality-related traits, from transient affective changes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ilija Tanasković, Ljiljana B. Lazarević, Goran Knežević, Nikola Milosavljević, Olga Dubljević, Bojana Bjegojević, Nadica Miljković. 2026-07-28. Interpretable machine learning for identifying individual-specific cardiogram signatures. https://arxiv.org/abs/2510.19775

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP