arXiv ScienceSearch

arXiv · 2510.14755

Impact of rotation on a cold atom interferometer and compensation strategy

Abstract

Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Noémie Marquet, Yannick Bidel, Malo Cadoret, Alexis Bonnin, Sylvain Schwartz, Phuong-Anh Huynh, Alexandre Bresson, Antoine Godard, Franck Pereira Dos Santos, Olivier Carraz, Nassim Zahzam. 2025-10-16. Impact of rotation on a cold atom interferometer and compensation strategy. https://arxiv.org/abs/2510.14755

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph