arXiv ScienceSearch

arXiv · 2510.06621

FEAorta: A Fully Automated Framework for Finite Element Analysis of the Aorta From 3D CT Images

Abstract

Aortic aneurysm disease ranks consistently in the top 20 causes of death in the U.S. population. Thoracic aortic aneurysm is manifested as an abnormal bulging of thoracic aortic wall and it is a leading cause of death in adults. From the perspective of biomechanics, rupture occurs when the stress acting on the aortic wall exceeds the wall strength. Wall stress distribution can be obtained by computational biomechanical analyses, especially structural Finite Element Analysis. For risk assessment, probabilistic rupture risk of TAA can be calculated by comparing stress with material strength using a material failure model. Although these engineering tools are currently available for TAA rupture risk assessment on patient specific level, clinical adoption has been limited due to two major barriers: labor intensive 3D reconstruction current patient specific anatomical modeling still relies on manual segmentation, making it time consuming and difficult to scale to a large patient population, and computational burden traditional FEA simulations are resource intensive and incompatible with time sensitive clinical workflows. The second barrier was successfully overcome by our team through the development of the PyTorch FEA library and the FEA DNN integration framework. By incorporating the FEA functionalities within PyTorch FEA and applying the principle of static determinacy, we reduced the FEA based stress computation time to approximately three minutes per case. Moreover, by integrating DNN and FEA through the PyTorch FEA library, our approach further decreases the computation time to only a few seconds per case. This work focuses on overcoming the first barrier through the development of an end to end deep neural network capable of generating patient specific finite element meshes of the aorta directly from 3D CT images.

Explore related subjects

Keep this discovery

BibTeXRIS

Jiasong Chen, Linchen Qian, Ruonan Gong, Christina Sun, Tongran Qin, Thuy Pham, Caitlin Martin, Mohammad Zafar, John Elefteriades, Wei Sun, Liang Liang. 2025-10-08. FEAorta: A Fully Automated Framework for Finite Element Analysis of the Aorta From 3D CT Images. https://arxiv.org/abs/2510.06621

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV