arXiv ScienceSearch

arXiv · 2508.01782

Joint Lossless Compression and Steganography for Medical Images via Large Language Models

Abstract

Recently, large language models (LLMs) have driven promising progress in lossless image compression. However, directly adopting existing paradigms for medical images suffers from an unsatisfactory trade-off between compression performance and efficiency. Moreover, existing LLM-based compressors often overlook the security of the compression process, which is critical in modern medical scenarios. To this end, we propose a novel joint lossless compression and steganography framework. Inspired by bit plane slicing (BPS), we find it feasible to securely embed privacy messages into medical images in an invisible manner. Based on this insight, an adaptive modalities decomposition strategy is first devised to partition the entire image into two segments, providing global and local modalities for subsequent dual-path lossless compression. During this dual-path stage, we innovatively propose a segmented message steganography algorithm within the local modality path to ensure the security of the compression process. Coupled with the proposed anatomical priors-based low-rank adaptation (A-LoRA) fine-tuning strategy, extensive experimental results demonstrate the superiority of our proposed method in terms of compression ratios, efficiency, and security. The source code will be made publicly available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pengcheng Zheng, Xiaorong Pu, Kecheng Chen, Jiaxin Huang, Meng Yang, Bai Feng, Yazhou Ren, Jianan Jiang, Chaoning Zhang, Yang Yang, Heng Tao Shen. 2026-07-24. Joint Lossless Compression and Steganography for Medical Images via Large Language Models. https://arxiv.org/abs/2508.01782

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TransUNet-GradCAM: A Hybrid Transformer-U-Net with Self-Attention and Explainable Visualizations for Foot Ulcer Segmentation

Automated segmentation of diabetic foot ulcers (DFUs) supports clinical diagnosis, treatment planning, and wound monitoring, but remains challenging because of heterogeneous appearance, irregular morphology, and cluttered backgrounds in clinical photographs. We evaluate a hybrid ViT-bottleneck U-Net that combines a convolutional encoder-decoder with a Transformer bottleneck and attention-gated skip connections. We emphasise rigorous validation and explainability rather than architectural novelty. The model was trained on the public Foot Ulcer Segmentation Challenge (FUSeg) dataset using a hybrid Dice and cross-entropy loss. Results are reported over five seeds as mean +/- 95% confidence interval at a fixed threshold. On the internal validation set, the model achieved a Dice of 0.8035 +/- 0.0053 and IoU of 0.7149 +/- 0.0073 (HD95 = 19.74 px, ASSD = 6.12 px). Ablation showed that only the hybrid loss significantly changed Dice (-0.038, p < 0.001), while the Transformer bottleneck, attention gates, and augmentation had small, non-significant in-domain effects. External validation without retraining achieved a Dice of 0.7460 on the AZH Wound Care Center cohort (n = 278), retaining about 92% of internal Dice. A small Medetec subset (n = 8) was used only for qualitative assessment, indicating partial rather than robust generalisation under domain shift. Explainability analysis found Grad-CAM more wound-localised (energy-in-mask 0.871 vs. 0.102), while attention rollout was significantly more faithful (p = 0.038, n = 200). Predicted and expert wound areas showed strong agreement (Pearson r = 0.944), with a lightweight model of 8.79 M parameters.

eess.IV

Constrained Color Carrier: Characterization-Preserving Conditional Color Rendering in Multi-Illuminant Camera Profiles

In Digital Negative (DNG) multi-illuminant profiles, characterization matrices and nonlinear rendering payloads share condition-dependent interpolation slots, so adding a slot for rendering capacity also introduces an additional characterization state. We introduce Constrained Color Carrier (CCC), which constructs the three pre-serialization ColorMatrix and ForwardMatrix states from the original dual matrix segments while allowing the same shared slots to carry three HueSatMap rendering bases. Condition-specific HueSatMap payloads are solved as numerical preimages of the target through a fixed serialized downstream rendering operator, and carrier selection enforces a preservation bound on the host-effective interpolated characterization. We evaluate CCC on the Sony ILCE-7RM5 Adobe Standard dual-illuminant profile using a white-balance-dependent Standard ColorCorrect target recovered from Phocus 4.0.1 for the Hasselblad X2D 100C. Using Euclidean Oklab error, CCC yields a worst-temperature 95th-percentile preservation error of 0.003857, below the prescribed tolerance of 0.004, and reduces the worst-condition 95th-percentile target error from 0.08208 for the Dual representation to 0.03508. The synthetic Ordinary Triple yields a preservation error of 0.014802 and exceeds the same tolerance. The serialized DNG Camera Profile (DCP) and Extensible Metadata Platform (XMP) artifacts reproduce the final color-table payloads exactly and yield zero numerical difference from solver-side offline execution, showing that the CCC solution is representable within the evaluated serialized profile format.

eess.IV

StainBridge: Stain-Aware Pairwise Registration of Serial Renal Biopsy Whole-Slide Images Across Structural and Immunohistochemical Stains

Three-dimensional (3D) reconstruction of histopathology tissue requires accurate pairwise registration of serial whole-slide images (WSIs). Cross-stain benchmarks have advanced registration of differently stained histology, including structural-to-immunohistochemistry (IHC) pairs, but serial renal biopsy stacks remain difficult: they interleave several structural stains with diverse IHC markers whose expression can be sparse or absent, leaving few shared features to match. We present StainBridge, a stain-aware framework for registering serial renal biopsy WSIs across structural and IHC stains. StainBridge couples three preprocessing components, stain deconvolution, intensity normalization, and tissue-mask injection, with XFeat-based affine initialization and four nonrigid backends (VoxelMorph, ConvexAdam, FireANTs, and DeeperHistReg). We evaluate it on 23 cases comprising 338 WSIs, four structural stains, and ten IHC markers, with functional tissue units annotated on consecutive sections to give 1,468 landmark correspondences across 272 image pairs, and report tissue-mask Dice, functional-unit centroid error in micrometers, and tissue-restricted structural similarity. Nonrigid refinement improves on the affine initialization for three of four backends, VoxelMorph being the exception. DeeperHistReg, which computes its own initialization rather than relying on XFeat, gives the best pooled landmark accuracy and registers the most pairs, including every attempted structural-IHC pair. Preprocessing improves landmark accuracy for ConvexAdam and FireANTs in every stain-pairing category, and FireANTs shows both the largest single preprocessing gain on structural-IHC pairs and the best pooled tissue overlap. These results offer practical guidance for cross-stain registration and a foundation for integrated 3D analysis of renal tissue architecture and molecular expression.

eess.IV