arXiv ScienceSearch

arXiv · 2507.14195

UWB Radar-based Heart Rate Monitoring: A Transfer Learning Approach

Abstract

Radar technology presents untapped potential for continuous, contactless, and passive heart rate monitoring via consumer electronics like mobile phones. However the variety of available radar systems and lack of standardization means that a large new paired dataset collection is required for each radar system. This study demonstrates transfer learning between frequency-modulated continuous wave (FMCW) and impulse-radio ultra-wideband (IR-UWB) radar systems, both increasingly integrated into consumer devices. FMCW radar utilizes a continuous chirp, while IR-UWB radar employs short pulses. Our mm-wave FMCW radar operated at 60 GHz with a 5.5 GHz bandwidth (2.7 cm resolution, 3 receiving antennas [Rx]), and our IR-UWB radar at 8 GHz with a 500 MHz bandwidth (30 cm resolution, 2 Rx). Using a novel 2D+1D ResNet architecture we achieved a mean absolute error (MAE) of 0.85 bpm and a mean absolute percentage error (MAPE) of 1.42% for heart rate monitoring with FMCW radar (N=119 participants, an average of 8 hours per participant). This model maintained performance (under 5 MAE/10% MAPE) across various body positions and heart rate ranges, with a 98.9% recall. We then fine-tuned a variant of this model, trained on single-antenna and single-range bin FMCW data, using a small (N=376, avg 6 minutes per participant) IR-UWB dataset. This transfer learning approach yielded a model with MAE 4.1 bpm and MAPE 6.3% (97.5% recall), a 25% MAE reduction over the IR-UWB baseline. This demonstration of transfer learning between radar systems for heart rate monitoring has the potential to accelerate its introduction into existing consumer devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elzbieta Gruzewska, Pooja Rao, Sebastien Baur, Matthew Baugh, Mathias M. J. Bellaiche, Sharanya Srinivas, Octavio Ponce, Matthew Thompson, Pramod Rudrapatna, Michael A. Sanchez, Lawrence Z. Cai, Timothy JA Chico, Robert F. Storey, Emily Maz, Umesh Telang, Shravya Shetty, Mayank Daswani. 2025-07-14. UWB Radar-based Heart Rate Monitoring: A Transfer Learning Approach. https://arxiv.org/abs/2507.14195

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

From Continuous sEMG Signals to Discrete Muscle State Tokens: A Robust and Interpretable Representation Framework

Surface electromyography (sEMG) signals exhibit substantial inter-subject variability and are highly susceptible to noise, posing challenges for robust and interpretable decoding. To address these limitations, we propose a discrete representation of sEMG signals based on a physiology-informed tokenization framework. The method employs a sliding window aligned with the minimal muscle contraction cycle to isolate individual muscle activation events. From each window, ten time-frequency features, including root mean square (RMS) and median frequency (MDF), are extracted, and K-means clustering is applied to group segments into representative muscle-state tokens. We also introduce a large-scale benchmark dataset, ActionEMG-43, comprising 43 diverse actions and sEMG recordings from 16 major muscle groups across the body. Based on this dataset, we conduct extensive evaluations to assess the inter-subject consistency, representation capacity, and interpretability of the proposed sEMG tokens. Our results show that the token representation exhibits high inter-subject consistency (Cohen's Kappa = 0.82+-0.09), indicating that the learned tokens capture consistent and subject-independent muscle activation patterns. In action recognition tasks, models using sEMG tokens achieve Top-1 accuracies of 75.5% with ViT and 67.9% with SVM, outperforming raw-signal baselines (72.8% and 64.4%, respectively), despite a 96% reduction in input dimensionality. In movement quality assessment, the tokens intuitively reveal patterns of muscle underactivation and compensatory activation, offering interpretable insights into neuromuscular control. Together, these findings highlight the effectiveness of tokenized sEMG representations as a compact, generalizable, and physiologically meaningful feature space for applications in rehabilitation, human-machine interaction, and motor function analysis.

eess.SP

Adaptive 3D-RoPE: Physics-Aligned Rotary Positional Encoding for Wireless Foundation Models

Wireless foundation models (WFMs) have emerged as a promising paradigm for unified channel state information (CSI) acquisition across diverse tasks in sixth-generation (6G) networks. Although WFMs significantly outperform task-specific small models, their zero-shot cross-scenario generalization still remains limited for real-world applications. Existing positional embeddings, the sole interface through which self-attention perceives the temporal-frequency-antenna 3D physical coordinates of CSI, fail to capture the highly dynamic and axis-dependent coherence inherent in wireless channels. This paper proposes Adaptive 3D-RoPE, a channel-driven 3D rotary positional embedding framework for WFMs to dynamically align the 3D positional embeddings with the instantaneous coherence state of heterogeneous CSI. The design proceeds in three stages: first, an axis-wise learnable rotary prior independently preserves the temporal, frequency, and antenna coordinate structures; second, a feature-guided rotary modulation module maps the feature-wise standard deviation of visible CSI tokens to compact, sample-adaptive scales; third, identical coordinate offsets induce dynamically adjusted query-key interactions tailored to the instantaneous channel state. Extensive experiments on both simulated and measured datasets validate the effectiveness of Adaptive 3D-RoPE across three complementary dimensions. It reduces NMSE by 10.14, 6.25, and 4.61 dB relative to baselines under antenna, temporal, and frequency scaling, respectively. It transfers effectively to real-world measured CSI and remains robust under imperfect CSI. Finally, it transfers to the independently designed LWM backbone and beam-prediction task, improving zero-shot Top-1 accuracy by 8.03 percentage points.

eess.SP

Multimodal Signal Restoration with Signed Twofold Graph Learning

We propose a method for jointly learning signed twofold graphs and performing signal restoration on multimodal graph signals. Multimodal signals on sensor networks are commonly modeled under the twofold graph assumption (TGA), which represents spatial structure and inter-modality relations as two separate graphs. Existing TGA-based signal restoration methods, however, either assume the graphs are known or restrict edge weights to be non-negative, preventing them from capturing negative inter-modal correlations. We address both limitations as follows. To learn twofold graphs from noisy and incomplete data, we formulate joint signal restoration and twofold graph learning as MAP estimation under a matrix normal prior, where the spatial and modality graph Laplacians appear directly as precision matrices. The resulting non-convex objective is solved by alternating minimization: The signal is updated via conjugate gradient applied to the arising Sylvester-type linear system; the graphs are updated via primal-dual hybrid gradient (PDHG). To capture negative inter-modal correlations, we estimate the signed structure of the modality graph from the dominant eigenspace of a complementary kernel matrix, which is then used in PDHG to update edge magnitudes. These iterative solvers are then unrolled into a feedforward network, with regularization weights and step sizes as layer-wise trainable parameters. Experiments on synthetic multimodal graph signals and two real-world datasets (Japan meteorological and Beijing air-quality data) confirm that the proposed method outperforms existing baselines across a range of noise levels and missing-data patterns; the learned graphs are also directly validated against the ground-truth graphs on the synthetic datasets.

eess.SP