arXiv ScienceSearch

arXiv · 2506.11327

Multi-angle precession electron diffraction (MAPED): a versatile approach to 4D-STEM precession

Abstract

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to non-integrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together post-acquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephanie M. Ribet, Rohan Dhall, Colin Ophus, Karen C. Bustillo. 2025-10-16. Multi-angle precession electron diffraction (MAPED): a versatile approach to 4D-STEM precession. https://doi.org/10.1093/mam%2Fozaf103

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A High Gain Preamplifier Board for Low Charge Semiconductor Detectors

We present a high-gain, low-noise preamplifier board designed for reading out low-charge semiconductor detectors--specifically Low-Gain Avalanche Detectors (LGADs) and three-dimensional (3D) silicon sensors--in high-energy physics applications. The circuit employs a three-stage architecture featuring a discrete SiGe:C bipolar junction transistor (BJT)-based transimpedance amplifier (TIA) front-end followed by two resistive feedback amplification stages using LTC6431 chips. This configuration achieves a charge gain of 115.27 mV ns/fC with excellent linearity over an input range of 0.5 fC to 25 fC and a wide bandwidth spanning from 34.0 MHz to 594.3 MHz. Experimental evaluations coupled with LGAD detectors demonstrate a time resolution of 36.41 ps and an equivalent noise charge (ENC) of 0.18 fC at 20 °C. Furthermore, tests with conventional PIN sensors without a gain layer yield a timing resolution of 76.10 ps with an ENC of 0.10 fC, and tests with the 3D silicon detector yield 39.40 ps with an ENC of 0.09 fC, all measured under the same thermal condition. All configurations confirm the board's capability in low-signal regimes, significantly outperforming previous reference designs. A six-channel variant of the board has also been developed to support position-sensitive measurements. These findings demonstrate the board's suitability for laboratory-based 4D tracking detector characterisation, while simultaneously providing the groundwork for dedicated ASIC development.

physics.ins-det

On the importance of cosmic-ray background in the Atomki anomaly

We report Geant4-based simulations of cosmic-ray muon backgrounds in models reproducing the geometries of the five-arm and six-arm e+e- pair spectrometers operated by the Atomki group at Debrecen. Full detector geometries are implemented for both setups, including position-sensitive detectors and plastic scintillators. In both configurations, cosmic muons generating two-arm coincidences produce statistically significant excesses in the opening-angle distribution whose positions are determined by the discrete azimuthal arrangement of detector arms and the plastic scintillators dimensions: in the six-arm spectrometer a peak appears near 140 degrees when the scintillator energy sum is selected in the 8Be transition window (16-20 MeV) and is suppressed for energy-asymmetric pairs, while a distinct peak near 120 degrees emerges in the 4He window (18-22 MeV), with no comparable enhancement in the respective background energy region. These angles, asymmetry dependences, and background characteristics show behaviours similar to those reported by the Atomki group as evidence for a 17 MeV boson. For the five-arm setup, a 140-degree excess is also reproduced at 8Be energies, and normalizing internal pair conversion events and cosmic coincidences to typical Atomki running conditions yields a cosmic-to-IPC ratio above unity in the signal window, indicating that the cosmic background is a leading contribution to the event rate at the energies and angles of interest. While they do not settle the question of the origin of the Atomki excesses, these results highlight the critical importance of a robust cosmic-ray treatment in this type of measurements, and call for a detailed description of the beam-off studies supporting the search for anomalies in the opening-angle vs. energy-sum distribution around the signal region.

physics.ins-det

Terahertz Radar Inversion for Range-Resolved Solids Concentration Profiling in Gas--Solid Flows

A stable inversion method is developed to reconstruct millimeter-scale solids-concentration profiles in particulate suspensions from monostatic sub-terahertz frequency-modulated continuous-wave (FMCW) radar measurements. In industrial particulate flows, cumulative attenuation renders the direct inversion of the path-integrated volume-scattering radar equation ill-conditioned. The method resolves this by an ensemble-averaged Mie-scattering closure coupled to a stable backward-integration scheme, yielding an analytical solution for the range-resolved solids concentration without case-specific parameter fitting against reference concentration measurements. The required range-dependent system response is determined by absolute near- and far-field calibration via external substitution with an electrically large metallic sphere. The method was evaluated against solids-volume-fraction estimates derived from differential-pressure measurements in a 3.1 m-tall circulating fluidized-bed riser operated with ambient air and copper powder (median diameter 32.6 $μ$m, density 8920 kg m$^{-3}$). The radar-derived and pressure-derived profiles agreed well across three superficial gas velocities producing distinct axial solids distributions, and the radar indicates sensitivity down to solids volume fractions of order $10^{-6}$.

physics.ins-det