Ultrasound transducers (UTs) are extensively used in several applications across a multitude of disciplines. A new type of UTs namely integrated photonic ultrasound transducers (IPUTs) possess superior performance due to the presence of optical interrogation systems, avoiding electric crosstalk and thermal electronic noise of the sensor. However, a major component of the IPUT's noise floor is its thermal acoustic noise. Several studies have been proposed to characterize IPUTs' behavior; nevertheless, these are either incomplete (model only the thermal noise) or targeted to characterize specific responses such as static behavior, in which the modeled receive transfer function (RTF) is about two orders lower than the experiments. In this study, we develop semi-analytical models based on time-domain finite element analysis and analytical expressions to characterize the RTF and thermal noise-induced noise equivalent pressure of IPUTs. We validate the models by comparing them with the literature, where we obtain a close match between them.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sabiju Valiya Valappil, Peter Harmsma, Maurits van der Heiden, Martin Verweij, Paul van Neer. 2025-06-03. Semi-analytical modeling of receive transfer function and thermal noise of integrated photonic ultrasound transducers. https://arxiv.org/abs/2506.02817

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Identifiability of the three-dimensional anisotropic thermal-conductivity tensor in thermoreflectance measurements: Single-orientation limits and full-tensor recover

Materials with full anisotropic thermal conductivity tensors are widely used in advanced applications, creating a need for dedicated characterization. Such tensors contain six independent components: three diagonal conductivities and three non-zero off-diagonal couplings. However, whether thermoreflectance measurements on a single crystalline orientation can uniquely determine an arbitrary tensor remains unclear. Here, we show that every fully anisotropic thermal-conductivity tensor admits a Schur-equivalent tensor with zero cross-plane couplings ($k_{xz}=k_{yz}=0$). The two tensors produce identical surface thermal responses, and this equivalence persists as frequency, delay time, beam geometry, and spatial offset vary. We further demonstrate that parameter-identifiability assessments based on heuristic interpretations of sensitivity trends or singular-value decomposition (SVD) of the sensitivity matrix cannot, by themselves, rule out globally equivalent solutions in fully anisotropic systems. Combining systematic analysis with numerical validation, we provide guidance on selecting signals and measurement orientations for full-tensor characterization. Specifically, measurements at three mutually orthogonal crystallographic orientations provide complementary information for full-tensor recovery. These findings clarify the limits of single-surface measurements and establish a systematic approach to characterizing fully anisotropic thermal-conductivity tensors.

physics.app-ph

Pushing the Dose Limit of Atomic-Resolution Imaging: A 4D-STEM case study of NaCl

Beam-induced damage fundamentally limits the characterization of beam-sensitive materials by scanning transmission electron microscopy (STEM), since structural information must be recorded before the electron beam irreversibly modifies the specimen. Here, sodium chloride (NaCl) is employed as a model beam-sensitive ionic crystal to investigate beam-induced structural evolution and the low-dose regime in which useful structural information can be recovered prior to significant damage. Four-dimensional STEM (4D-STEM) datasets were acquired at 200 kV using a Timepix3 direct electron detector and reconstructed using real-time integrated centre of mass (riCoM) imaging. We first establish the characteristic damage behavior of NaCl under high electron doses. Across different dwell times and raster scan orientations, damage develops reproducibly into square-faceted voids whose boundaries align with the 100 crystallographic directions of the rock-salt lattice, indicating that the morphology is governed predominantly by the intrinsic crystallography rather than the scan geometry. We then investigate the low-dose imaging regime using dose-fractionated acquisitions. At 130 e-A-2 per frame, normalized cross-correlation with respect to the first frame quantitatively tracks progressive structural degradation and enables the onset of measurable damage to be identified as a function of accumulated dose. A subsequent acquisition at 32 e-A-2 per frame demonstrates that atomic-scale spatial information can still be recovered below this damage threshold. These results demonstrate how dose-efficient 4D-STEM acquisition combined with riCoM imaging can extend the accessible imaging regime of highly beam-sensitive ionic materials while preserving atomic-scale information.

physics.app-ph

Fast, optimal readout of a tethered optomechanical pressure sensor

We demonstrate a fast readout method for tethered optomechanical pressure sensors. The fast readout method allows mechanical ring-down measurement rates that exceed the total mechanical damping rate $Γ_t$. We model the uncertainty of our ring-down measurements with the Cramér-Rao bound, including the effect of thermomechanical noise. Both our data and the Cramér-Rao bound indicate that measurement rates on the order of the mechanical damping rate produce the lowest uncertainty. At low pressures, using the optimal measurement rate allows 10$\times$ faster measurements or 3$\times$ lower uncertainty compared to allowing our sensor to ring down to the thermomechanical noise floor. Our results allow tethered optomechanical pressure sensors to operate at rates comparable to commercially available pressure gauges, removing an obstacle to adoption of optomechanical pressure sensors in industrial settings.

physics.app-ph