Automated Fetal Biometry Assessment with Deep Ensembles using Sparse-Sampling of 2D Intrapartum Ultrasound Images

Abstract

The International Society of Ultrasound advocates Intrapartum Ultrasound (US) Imaging in Obstetrics and Gynecology (ISUOG) to monitor labour progression through changes in fetal head position. Two reliable ultrasound-derived parameters that are used to predict outcomes of instrumental vaginal delivery are the angle of progression (AoP) and head-symphysis distance (HSD). In this work, as part of the Intrapartum Ultrasounds Grand Challenge (IUGC) 2024, we propose an automated fetal biometry measurement pipeline to reduce intra- and inter-observer variability and improve measurement reliability. Our pipeline consists of three key tasks: (i) classification of standard planes (SP) from US videos, (ii) segmentation of fetal head and pubic symphysis from the detected SPs, and (iii) computation of the AoP and HSD from the segmented regions. We perform sparse sampling to mitigate class imbalances and reduce spurious correlations in task (i), and utilize ensemble-based deep learning methods for task (i) and (ii) to enhance generalizability under different US acquisition settings. Finally, to promote robustness in task iii) with respect to the structural fidelity of measurements, we retain the largest connected components and apply ellipse fitting to the segmentations. Our solution achieved ACC: 0.9452, F1: 0.9225, AUC: 0.983, MCC: 0.8361, DSC: 0.918, HD: 19.73, ASD: 5.71, $Δ_{AoP}$: 8.90 and $Δ_{HSD}$: 14.35 across an unseen hold-out set of 4 patients and 224 US frames. The results from the proposed automated pipeline can improve the understanding of labour arrest causes and guide the development of clinical risk stratification tools for efficient and effective prenatal care.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jayroop Ramesh, Valentin Bacher, Mark C. Eid, Hoda Kalabizadeh, Christian Rupprecht, Ana IL Namburete, Pak-Hei Yeung, Madeleine K. Wyburd, Nicola K. Dinsdale. 2025-05-20. Automated Fetal Biometry Assessment with Deep Ensembles using Sparse-Sampling of 2D Intrapartum Ultrasound Images. https://arxiv.org/abs/2505.14572

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Hyperspectral Image Restoration and Super-resolution with Physics-Aware Deep Learning for Biomedical Applications

Hyperspectral imaging is a powerful bioimaging tool which can uncover novel insights, thanks to its sensitivity to the intrinsic properties of materials. However, this enhanced contrast comes at the cost of system complexity, constrained by an inherent trade-off between spatial, spectral, and temporal resolution. To overcome this limitation, we present a self-supervised deep learning-based approach that restores and enhances pixel resolution post-acquisition without requiring external training data beyond the images to be restored. Fine-tuned using metrics aligned with the imaging model, our physics-aware method achieves a 16$\times$ pixel super-resolution enhancement and a 12$\times$ imaging speedup without the need of additional training data for transfer learning. Applied to both synthetic and experimental data from five different sample types, including healthy and diseased tissues, we demonstrate that the model preserves biological integrity, as we did not detect systematic loss of biological features or biologically consequential hallucinations in tested datasets. We also concretely demonstrate the model's ability to reveal disease-associated metabolic changes that would otherwise remain undetectable. Furthermore, we provide physical insights into the model's inner workings, paving the way for future refinements that could potentially reveal novel high resolution features in an explainable manner. All methods are available as open-source software on GitHub.

eess.IV

OASIS: Online Adaptive Video Compression via Closed-loop Feedback Control

Computer vision systems are a key building block in an autonomous vehicle, responsible for a range of perception tasks. However, they incur massive data transmission over long communication links from multiple cameras, creating a critical bandwidth and energy bottleneck. Although conventional codecs such as H.264 can reduce data rates, they are ill-suited for real-time vision systems due to high processing latency and energy consumption, as well as their reliance on static user-defined compression settings. In light of these challenges, we propose OASIS, an adaptive video compression framework that integrates lightweight in-sensor compression with task-aware compression ratio control. Based on the real-time task performance, it dynamically updates the optimal compression ratio. Experimental results demonstrate that OASIS generalizes across multiple vision tasks, achieving on average a 6x data compression, 5.8x reduction in link power consumption, and 2.5x reduction in link latency, with at most 1.5% performance degradation.

eess.IV

Echo-E$^3$Net: Efficient Endocardial Spatio-Temporal Network for Ejection Fraction Estimation

Left ventricular ejection fraction (LVEF) is a primary marker of cardiac function. However, routine estimation from endocardial measurements requires manual delineation at end-diastole (ED) and end-systole (ES), a process that is time-consuming and subject to inter-observer variability. Reliable automation is especially valuable for point-of-care ultrasound (POCUS), where computational resources are limited and acquisition quality varies. We propose Echo-E$^3$Net, an anatomy-guided spatio-temporal network that explicitly embeds cardiac anatomy into LVEF prediction. A dual-phase Endocardial Border Detector (E$^2$CBD) uses phase-specific cross-attention to localize ED/ES endocardial landmarks and produce phase-aware landmark embeddings, while an Endocardial Feature Aggregator (E$^2$FA) fuses these embeddings with global statistical descriptors of deep feature maps to refine EF regression. Training is guided by a lightweight geometric loss that uses ED and ES endocardial landmarks to regularize EF prediction. On EchoNet-Dynamic and a PSAX subset of EchoNet-Pediatric, Echo-E$^3$Net attains competitive performance using only 1.55M parameters and 8.05 GFLOPs, an order-of-magnitude compute reduction versus recent baselines, supporting real-time deployment. Our code is publicly available at https://github.com/moeinheidari7829/Echo-E3Net.

eess.IV