arXiv ScienceSearch

arXiv · 2504.16811

A novel method for measuring the attenuation length and the group velocity of transparent liquids in a variable length cavity

Abstract

The transparency of liquid scintillators or water is an important parameter for many detectors in particle and astroparticle physics. In this work, the Cavity Enhanced Long Light Path Attenuation Length Screening (CELLPALS) method for the determination of the attenuation length is presented for the first time. The method is based on an experimental setup similar to a Fabry-P\'erot interferometer but adding up multiple-reflected intensities of a modulated light source. CELLPALS was developed to measure the attenuation length of highly transparent liquids (> 10 m) with significantly lower uncertainties than with UV-Vis spectroscopy, which is a standard method for determining the attenuation length. In addition to the attenuation length, the group velocity of light in the sample can also be derived from the free spectral range of the cavity, which is not provided by any conventional method for determining the attenuation length. In this work, the CELLPALS method, its achievable precision and an experimental setup to demonstrate its feasibility are discussed. The attenuation lengths and group velocities of several transparent liquids were measured at wavelengths between 420 nm and 435 nm. In addition, the attenuation length and group velocity of linear alkylbenzene (LAB) samples after different purification stages and a purified LAB-based liquid scintillator were measured at a wavelength of 425 nm. The results confirmed the potential of CELLPALS to determine the attenuation length with an uncertainty of ~ 2 %. The group velocity of light in the sample can be determined with an uncertainty of ~ 0.03 %.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jessica Eck, Dhanushka Bandara, Gina Grünauer, Tobias Heinz, Tobias Lachenmaier. 2025-04-23. A novel method for measuring the attenuation length and the group velocity of transparent liquids in a variable length cavity. https://doi.org/10.1016/j.nima.2025.170507

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det