arXiv · 2502.17287
Automated generation of epilepsy surgery resection masks; The RAMPS pipeline
Abstract
MRI-based delineation of brain tissue removed by epilepsy surgery can be challenging due to post-operative brain shift. In consequence, most studies use manual approaches which are prohibitively time-consuming for large sample sizes, require expertise, and can be prone to errors. We propose RAMPS (Resections And Masks in Preoperative Space), an automated pipeline to generate a 3D resection mask of pre-operative tissue. Our pipeline leverages existing software including FreeSurfer, SynthStrip, Sythnseg and ANTS to generate a mask in the same space as the patient's pre-operative T1 weighted MRI. We compare our automated masks against manually drawn masks and two other existing pipelines (Epic-CHOP and ResectVol). Comparing to manual masks (N=87), RAMPS achieved a median(IQR) dice similarity of 0.86(0.078) in temporal lobe resections, and 0.72(0.32) in extratemporal resections. In comparison to other pipelines, RAMPS had higher dice similarities (N=62) (RAMPS:0.86, Epic-CHOP: 0.72, ResectVol: 0.72). We release a user-friendly, easy to use pipeline, RAMPS, open source for accurate delineation of resected tissue.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Callum Simpson, Gerard Hall, John S. Duncan, Yujiang Wang, Peter N. Taylor. 2025-02-24. Automated generation of epilepsy surgery resection masks; The RAMPS pipeline. https://arxiv.org/abs/2502.17287
Cite the original work for its findings. Save a collection to share your selection of sources.