arXiv ScienceSearch

arXiv · 2501.09116

Deep Distance Map Regression Network with Shape-aware Loss for Imbalanced Medical Image Segmentation

Abstract

Small object segmentation, like tumor segmentation, is a difficult and critical task in the field of medical image analysis. Although deep learning based methods have achieved promising performance, they are restricted to the use of binary segmentation mask. Inspired by the rigorous mapping between binary segmentation mask and distance map, we adopt distance map as a novel ground truth and employ a network to fulfill the computation of distance map. Specially, we propose a new segmentation framework that incorporates the existing binary segmentation network and a light weight regression network (dubbed as LR-Net). Thus, the LR-Net can convert the distance map computation into a regression task and leverage the rich information of distance maps. Additionally, we derive a shape-aware loss by employing distance maps as penalty map to infer the complete shape of an object. We evaluated our approach on MICCAI 2017 Liver Tumor Segmentation (LiTS) Challenge dataset and a clinical dataset. Experimental results show that our approach outperforms the classification-based methods as well as other existing state-of-the-arts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Huiyu Li, Xiabi Liu, Said Boumaraf, Xiaopeng Gong, Donghai Liao, Xiaohong Ma. 2025-01-15. Deep Distance Map Regression Network with Shape-aware Loss for Imbalanced Medical Image Segmentation. https://doi.org/10.1007/978-3-030-59861-7_24

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

OmniRAS: Standardizing Foundation Model Training and Evaluation in Robot-Assisted Surgery

Few foundation models exist for robot-assisted surgery, partly because large robotic-surgery video corpora are difficult to assemble and existing models are evaluated mostly on laparoscopic benchmarks. Further, most existing models are evaluated on a small set of public benchmarks, mostly focused on laparoscopic surgery. We present OmniRAS, a family of 1B- and 2B-parameter V-JEPA-2.1 encoders for robot-assisted surgery, and detail their training. First, we release two densely annotated robotic-cholecystectomy datasets: OmniRAS-PR and a multi-label YT-Chole tool-verb-target task, the first triplet-style annotation for robotic cholecystectomy, together with splits, probe protocols, and an inter-rater study validating the shared phase ontology. Second, we document continued pretraining at up to 256 compute nodes with global batch 6,144 over 19 sources totaling approximately 2,650 hours of surgical video, 51% robotic, and analyze compute and data composition. Third, we evaluate against raw V-JEPA-2.1 and specialized surgical models on six tasks spanning triplet, phase, and step recognition, action segmentation, and detection, under frozen-encoder and final-four-block fine-tuning regimes. Across three seeds, this yields 254 downstream runs, including 109 with partial backbone fine-tuning. The best OmniRAS models achieve the strongest adapted results across all task families, while frozen differences are smaller.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV