Effect of the geometry of butt-joint implant-supported restorations on the fatigue life of prosthetic screws

Abstract

Statement of problem. Dental implant geometry affects the mechanical performance and fatigue behavior of butt-joint implant-supported restorations. However, failure of the implant component has been generally studied by ignoring the prosthetic screw, which is frequently the critical restoration component Purpose. Evaluate the effect of 3 main implant geometric parameters: the implant body diameter, the platform diameter, and the implant-abutment connection type (external versus internal butt-joint) on the fatigue life of the prosthetic screw. The experimental values were further compared with the theoretical ones obtained by using a previously published methodology M&M. 4 different designs of direct-to-implant dental restorations from the manufacturer BTI were tested. Forty-eight fatigue tests were performed in an axial fatigue testing machine according to ISO 14801. Linear regression models, 95% interval confidence bands for the linear regression, and 95% prediction intervals of the fatigue load-life results were obtained and compared through an analysis of covariance to determine the influence of the 3 parameters under study on the fatigue behavior Results. Linear regression models showed a statistical difference when the implant body diameter was increased by 1 mm; an average 3.5-fold increase in fatigue life was observed. Increasing the implant abutment connection diameter by 1.4 mm also showed a significant difference, leading to 7-fold longer fatigue life on average. No significant statistical evidence was found to demonstrate a difference in fatigue life between internal and external connections Conclusions. Increasing the implant platform and body diameter significantly improved the fatigue life of the screw, whereas external and internal connections provided similar results. In addition, experimental results proved the accuracy of the fatigue life prediction methodology

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mikel Armentia, Mikel Abasolo, Ibai Coria, Nicolas Saintier. 2024-11-07. Effect of the geometry of butt-joint implant-supported restorations on the fatigue life of prosthetic screws. https://doi.org/10.1016/j.prosdent.2021.12.010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms

Conservative dose remapping can be formulated by transporting mass and deposited energy across nonmatching grids, but fixed high-sampling calculations use the same work for easy and difficult cases. We developed conformal multiresolution error control (CoMERC), a fail-closed multilevel quasi-Monte Carlo (QMC) controller for reference-relative target-cell allocation error in a fixed piecewise-constant source model with known deformation. Two randomized nested replicates were evaluated at a probe level of 4 and candidate levels of 8 and 16. Four endpoints were controlled jointly: reference-mass-weighted global, high-gradient, and density-gradient-threshold root-mean-square error, plus eligible-cell maximum absolute error. A split-conformal multiplier was calibrated from 240 synthetic cases, frozen, and evaluated on 400 independent cases from the same generator and 120 cases from a prespecified shifted generator. In the primary set, joint coverage was 394/400 (98.50%; one-sided 95% lower limit, 97.06%), 388/400 cases (97.00%; lower limit, 95.18%) received an output, and 0/388 released outputs exceeded any tolerance (one-sided 95% upper limit, 0.769%). Final actions were level 8 for 190 cases, level 16 for 198, and ABSTAIN for 12. The frozen policy implied mean relative production-sample work of 0.5844 compared with always running both randomized replicates through level 16; the prespecified 95th-percentile bootstrap upper limit was 0.6194. All seven primary gates passed. In the shifted-generator set, 113/120 cases were released and one released output exceeded a tolerance. CoMERC provided marginal finite-sample error control and lower modeled production-sample work in the locked synthetic population, but not patient-level, registration-level, conditional-on-release, or clinical safety validation.

physics.med-ph

Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices

Background and purpose: Dose Volume Histogram (DVH) indices remain the main dose-effect metrics for toxicity prediction, but they depend on how contours were made. Inter-observer variability (IOV) is unavoidable and clinically accepted, so the question for automatic segmentation addresses equivalence: do automatic contours produce DVH errors comparable to human IOV, and can these indices predict patient-reported toxicity? Materials and methods: In 429 patients treated with iodine-125 LDR-BT monotherapy, indices from expert manual delineation were compared with a deterministic and a Bayesian nnUNet on a fixed dose distribution, by two-one-sided tests against margins set from CT contouring IOV. Logistic regression gave patient-level thresholds at 90\,\% probability of equivalence. In 380 patients, eleven DHV indices were added to a clinical baseline predicting change in International Prostate Symptom Score (IPSS) at six horizons over 5 years, with nested cross-validation, bootstrap intervals and corrected $t$-tests. Results: All cohort-level comparisons of DVH indices were declared equivalent, with no interval consuming more than 44\,\% of its equivalence margin. Individual agreement was weaker with equivalence rates from 55.9\,\% to 89.7\,\%, depending on the DVH index and automatic segmentation model. Thresholds ranged from 0.864 to 0.958 Dice. No DVH block improved IPSS prediction at any horizon. The largest improvement declared by bootstrap intervals was 0.12 IPSS points, well below the minimal clinically important difference, across all learners. Conclusion: Automatic contours matched expert dosimetry within human IOV on average, but individual equivalence requires a volume dependent quality metric threshold definition. Our DVH indices panel provides no significant predictive power for IPSS, irrespective of segmentation source and horizon.

physics.med-ph

The Electrodynamic Basis of Dichroism-Mediated Polarization Perception

Humans see the polarization of light through entoptic percepts arising from the macula's Henle fiber layer, where xanthophyll pigments absorb preferentially across the radiating fibers. From the layer's complex dielectric tensor alone, Maxwell's equations in Berreman $4\times4$ form yield its Mueller matrix, set by four scalars $\{A,B,C,D\}$. Its intensity channel depends only on the dichroic pair $A$ and $B$, which fix the percepts at a maximum contrast $|B|/A\approx0.05$. One relation generates the whole dichroism-mediated family: Haidinger's brushes under a uniform field, their dark arms perpendicular to the $\mathbf{E}$-vector; fractured brushes under spatially varying fields; and $N$-fold brushes under vector-vortex illumination.

physics.med-ph