arXiv ScienceSearch

arXiv · 2410.14474

On the Influence of Parallax Effects in Thick Silicon Sensors in Coherent Diffraction Imaging

Abstract

Structure determination is a key application of XFELs and 4th generation synchrotron sources, particularly using the coherent and pulsed X-ray radiation from X-ray free-electron lasers (XFEL). Scientific interest focuses on understanding the physical, biological, and chemical properties of samples at the nanometer scale. The X-rays from XFELs enable Coherent X-ray Diffraction Imaging (CXDI), where coherent X-rays irradiate a sample, and a far-field diffraction pattern is captured by an imaging detector. By the nature of the underlying physics, the resolution, at which the sample can be probed with the CXDI technique, is limited by the wavelength of the X-ray radiation and the exposure time if a detector can record the diffraction pattern to very large scattering angles. The resolution that can be achieved under real experimental conditions, depends strongly on additional parameters. The Shannon pixel size, linked to the detector resolution, the coherent dose that can be deposited in the sample without changing its structure, the image contrast, and the signal-to-noise ratio of the detected scattered radiation at high $q$, i.e. at high scattering angles $2\Theta$, have a strong influence on the resolution. The signal-to-noise ratio at high $q$ defines the "effective" maximum solid angle in a specific experiment setup up to which a detector can efficiently detect a signal and in consequence determines the achievable resolution. The image contrast defines how well bright image features can be distinguished from dark ones. We present the preliminary results of our study on the influence of the PSF on SNR, image contrast, position resolution, and achievable sample resolution for different pixel sizes.

Explore related subjects

Keep this discovery

BibTeXRIS

Markus Kuster, Robert Hartmann, Steffen Hauf, Peter Holl, Tonn Rüter, Lothar Strüder. 2024-10-18. On the Influence of Parallax Effects in Thick Silicon Sensors in Coherent Diffraction Imaging. https://arxiv.org/abs/2410.14474

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det