Detection of High-Impedance Low-Current Arc Faults at Electrical Substations

Abstract

Arcing faults in low voltage (LV) distribution systems associated with arc-flash risk and potentially significant equipment damage are notoriously difficult to detect under some conditions. Especially so when attempting to detect using sensing at the line, high voltage side of a substation transformer. This paper presents an analytics-based physics-aware approach to detect high-impedance, low-current arcing faults from the primary side of the substation transformer at current thresholds, below normal operating events, along with transformer inrush currents. The proposed methodology leverages the Hankel Alternative View Of Koopman Operator approach to differentiate arcing faults from standard operations, while the Series2Graph method is employed to identify the time of fault occurrence and duration. Unlike prior studies that detect such faults at the device or secondary transformer side, this work demonstrates successful fault detection at the primary side of the distribution substation transformer for faults occurring on the secondary side. The approach addresses the practical challenges of differentiating primary side expected and acceptable transients from similar magnitude LV arcing fault currents that may occur on the secondary side. The results demonstrate the efficacy of the proposed method in accurately identifying fault occurrence and duration, minimizing the risk of false positives during similar characteristic events, thus improving the reliability and operational efficiency of power distribution systems. This approach can benefit both traditional and smart power grids that employ similar transformer configurations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K. Victor Sam Moses Babu, Divyanshi Dwivedi, Marcelo Esteban Valdes, Pratyush Chakraborty, Prasanta Kumar Panigrahi, Mayukha Pal. 2024-10-14. Detection of High-Impedance Low-Current Arc Faults at Electrical Substations. https://arxiv.org/abs/2410.10151

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Cooperative Multi-Agent Assignment over Stochastic Graphs via Constrained Reinforcement Learning

Constrained multi-agent reinforcement learning offers the framework to design scalable and almost surely feasible solutions for teams of agents operating in dynamic environments to carry out conflicting tasks. We address the challenges of multi-agent coordination through an unconventional formulation in which the dual variables are not driven to convergence but are free to cycle, enabling agents to adapt their policies dynamically based on real-time constraint satisfaction levels. The coordination relies on a light single-bit communication protocol over a network with stochastic connectivity. Using this gossiped information, agents update local estimates of the dual variables. Furthermore, we modify the local dual dynamics by introducing a contraction factor, which lets us use finite communication buffers and keep the estimation error bounded. Under this model, we provide theoretical guarantees of almost sure feasibility and corroborate them with numerical experiments in which a team of robots successfully patrols multiple regions, communicating under a time-varying ad-hoc network.

eess.SY

Which Top Energy-Intensive Manufacturing Countries Can Compete in a Renewable Energy Future?

In a world increasingly powered by renewables and aiming for greenhouse gas-neutral industrial production, the future competitiveness of todays top manufacturing countries is questioned. This study applies detailed energy system modeling to quantify the Renewable Pull, an incentive for industry relocation exerted by countries with favorable renewable conditions. Results reveal that the Renewable Pull is not a cross-industrial phenomenon but strongly depends on the relationship between energy costs and transport costs. The intensity of the Renewable Pull varies, with China, India, and Japan facing a significantly stronger effect than Germany and the United States. Incorporating national capital cost assumptions proves critical, reducing Germanys Renewable Pull by a factor of six and positioning it as the second least affected top manufacturing country after Saudi Arabia. Using Germany as a case study, the analysis moreover illustrates that targeted import strategies, especially within the EU, can nearly eliminate the Renewable Pull, offering policymakers clear options for risk mitigation.

eess.SY

Certifying Frequency Stability for Systems with Line Dynamics and Heterogeneous Bus Dynamics

This work presents a framework for certifying small-signal frequency stability of a power system with line dynamics and heterogeneous bus dynamics. This framework can certify the stability of systems which include synchronous generators, synchronous condensers, and converter-interfaced resources with a wide range of controls. Moreover, it can do so without detailed or precise knowledge of the network topology. With this framework, we also provide a detailed analysis of how proportional-derivative (PD) droop can improve the stability margin of the frequency response. The stability certificates presented in this work, which extend prior results by incorporating line dynamics, provide insight into how the control parameters for different units in the system impact the overall frequency stability. While damper windings have long been understood to improve the frequency synchronization between machines, the dynamics of the damper windings are complex, making them difficult to analyze. To address this gap, this paper derives a novel reduced-order model of the damper windings in the form of a derivative droop term. Moreover, we show that derivative droop terms used in grid-forming (GFM) control can be understood as a form of damper winding emulation. Our analytical stability conditions highlight the importance of damper windings (or their emulation) in facilitating frequency synchronization and suppressing unstable interactions between GFM converters. These results are validated with electromagnetic-transient (EMT) simulation.

eess.SY